Results 101 to 110 of about 338,380 (131)
ZnO varistors are widely used in the field of lightning protection. After being struck by lightning, ZnO varistors absorb heat, which can lead to temperature rise and even damage, posing a serious safety threat to electrical safety.
Li Chunying, Zhang Chunlong, Lv Qing
doaj +1 more source
On the influence of corona on lightning-induced overvoltages
An experimentally inferred charge-voltage (Q-V) diagram used to macroscopically model the corona phenomenon is adopted for the calculation of the lightning-induced transients in presence of corona. The paper aim at presenting the calculation procedure as
PAOLONE, MARIO +3 more
core +2 more sources
Single level impulse generator
Voltage Vs Time data taken from numerical computing environment after simulating single level impulse generator circuit. Peak voltage in this data-set achieved 4.2 Megavolts of voltage according to lightning properties published in various literature. It
Jana, S
core +2 more sources
The effect of multiple lightning impulse on the electrical characteristics of transient voltage suppression diode as low voltage lightning protective device [PDF]
The behaviour and performance of surge protective devices such as transient voltage suppression (TVS) diode under the application of multiple lightning impulses are different from the single lightning impulse.
Azmi, Azralmukmin
core
Current Sensor with Optimized Linearity for Lightning Impulse Current Measurement
Impulse current measurement technology is widely used in various applications, including lightning protection monitoring in power systems, welding current measurement in aircraft and shipbuilding industries, as well as high-current measurement in pulsed ...
Wenting Li +7 more
doaj +1 more source
This study examines and compares the breakdown and aging properties of five insulating liquids. Additionally, the influence of different voltage polarities on these properties was analyzed to investigate the effect of aging on polarity behavior under ...
Sabrina Krügel, Ronald Plath
doaj +1 more source
Worldwide comparison of lightning impulse voltage measuring systems at the 400-kV level
An international comparison of lightning and switching impulse voltage measuring systems was arranged and coordinated by the Helsinki University of Technology (MIKES-TKK), Espoo, Finland, between 1999 and 2002.
Juvik, J.I. +32 more
core +1 more source
The calculation of the series gap distance of the lightning protection device in the 10 kV distribution network is rough, and the positioning error of the lightning strike point may be large, which affects the stability of electricity consumption ...
Fengwen Chen
doaj +1 more source
Lightning earthing evaluation by impulse and high frequency methods [PDF]
Uziemienia odgromowe przeznaczone do odprowadzania do ziemi prądów piorunowych pracują w zakresie znacznie szybszych przebiegów (žs) niż uziemienia robocze (ms), a więc wymagają innych metod badań, zwłaszcza uwzględniających spadki indukcyjne w systemie ...
Wojtas, S.
core
(A) Study on the Electrical Characteristics of ZnO Blocks by a Multiple-Lightning Impulse Current [PDF]
This thesis deals with the changes of the electrical characteristics of ZnO blocks by the application of a single and a multiple-lightning impulse current.
李鐘赫
core

