Results 61 to 70 of about 298,299 (227)
Lightning Impulse Current Tests on some Electroconductive Fabrics [PDF]
On the search of lightweight lightning protection materials that can be used as part of lightning protection systems, we investigate some types of electroconductive fabrics by applying several lightning impulse currents in laboratory.
Q., Liz K. Herrera +11 more
core +1 more source
Breakdown process on rod–rod air gap under oscillating lightning impulse voltage
This study presents the discharge process on rod–rod electrodes under oscillating lightning impulse voltage. For this purpose, a measurement system has been developed to record the discharge currents at both rod electrodes simultaneously and to ...
Akif Gürlek
doaj +1 more source
Lightning Impulse Voltage Stresses In Underground Cables
Abstract Underground power cables are crucial for transmission and distribution. Lightning can stress their insulation, but not directly. So, impulse cable testing is studied. This research examines the cable’s transient response to standard and non-standard lightning impulse voltage waveforms.
M S Laili +4 more
openaire +1 more source
Comparison of Dielectric Recovery After Arc Burning in SF6 Gas and Its Potential Alternatives
ABSTRACT Although sulphur hexafluoride (SF6) exhibits exceptional insulating properties, it is a potent greenhouse gas. Therefore, studying alternatives to SF6 is critical for developing environmentally friendly high‐voltage electrical equipment.
Ziqi Liu +4 more
wiley +1 more source
ABSTRACT This paper investigates the generation mechanism of quasi‐power‐frequency resonant overvoltage triggered by multiple lightning strikes in high‐voltage alternating current (HVAC) systems equipped with shunt reactors. Based on field measurements from a 500 kV AC system, equivalent and simplified circuit models have been established to analyse ...
Tao Liang +7 more
wiley +1 more source
Effects of Lightning Impulses on the Dielectric Properties of HDPE
Impulse over-voltages are very common phenomena in electric power systems. Switching impulses are created by switching surges or local faults while lightning impulses are due to lightning strikes to overhead lines.
Dao, N L, Swingler, S G, Lewin, P L
core +1 more source
ABSTRACT Strong wind–sand weather in Xinjiang threatens power grid safety by increasing transmission line tripping risks. Existing studies focus on sand polarization but neglect the coupled influence of high‐speed airflow and charged sand on gap discharge characteristics.
Jianghai Geng +8 more
wiley +1 more source
On the classification of self-triggered versus other-triggered lightning flashes [PDF]
We present in this paper lightning current measurements and LMA (Lightning Mapping Array) data associated with upward flashes observed at the Sàntis Tower during Summer 2017.
Sunjerga, A. +27 more
core +1 more source
This study presents findings on the influence of gap length distance on the lightning impulse breakdown voltage of three dielectric liquids of different chemical origins.
Wiktor Kunikowski +5 more
doaj +1 more source
Study on the Power‐Frequency Arc Extinction Characteristics of Semi‐Closed Short‐Gap Device
ABSTRACT Multi‐chamber arc‐extinguishing devices have a simple structure and excellent arc‐extinguishing performance; thus, they have attracted considerable attention as lightning protection devices. However, the structural parameters of different models of the aforementioned devices vary, leading to inconsistent protection levels; therefore, the arc ...
Yeqiang Deng +4 more
wiley +1 more source

