Results 51 to 60 of about 1,358 (191)

Breakdown process on rod–rod air gap under oscillating lightning impulse voltage

open access: yesHigh Voltage, 2020
This study presents the discharge process on rod–rod electrodes under oscillating lightning impulse voltage. For this purpose, a measurement system has been developed to record the discharge currents at both rod electrodes simultaneously and to ...
Akif Gürlek
doaj   +1 more source

Mechanism Analysis and Multiphysics Validation of Lightning Attenuation in Constrained Space

open access: yesIEEE Access, 2022
The problem of resistance reduction has always been the key and difficult point of lightning protection. However, the problem of reducing the grounding resistance efficiently has not been solved. A method is introduced in this paper to solve this problem
Yang Lu   +3 more
doaj   +1 more source

From Ashes to Action: Economic Growth, Ecological Footprint, and Forest Fire Resilience in Advanced and Emerging Economies

open access: yesLand Degradation &Development, EarlyView.
ABSTRACT Forest fires have escalated alarmingly, now consuming more than double the tree cover compared to two decades ago, signaling a growing and urgent environmental crisis. This study addresses the ever increasing global concern of forest fires, focusing on sustainable economic recovery while minimizing the ecological footprint amid mounting ...
Laxita Soontha   +2 more
wiley   +1 more source

Lightning Impulse Voltage Stresses In Underground Cables

open access: yesJournal of Physics: Conference Series, 2023
Abstract Underground power cables are crucial for transmission and distribution. Lightning can stress their insulation, but not directly. So, impulse cable testing is studied. This research examines the cable’s transient response to standard and non-standard lightning impulse voltage waveforms.
M S Laili   +4 more
openaire   +1 more source

Evaluation Methodology, Numerical Verification and Retrofilling Procedure for Power Transformers to Ensure K‐Class Flame Retardancy and Environmentally Friendly

open access: yesHigh Voltage, EarlyView.
ABSTRACT With increasing demands for fire safety and environmental friendliness, retrofilling transformers with alternative insulating liquids has become a growing trend. However, retrofilling power transformers remains uncertain, as more residual mineral oil compromises K‐class flame retardancy, and its impact on environmental performance has yet to ...
Zhenfu Tang   +5 more
wiley   +1 more source

Comparison of Dielectric Recovery After Arc Burning in SF6 Gas and Its Potential Alternatives

open access: yesHigh Voltage, EarlyView.
ABSTRACT Although sulphur hexafluoride (SF6) exhibits exceptional insulating properties, it is a potent greenhouse gas. Therefore, studying alternatives to SF6 is critical for developing environmentally friendly high‐voltage electrical equipment.
Ziqi Liu   +4 more
wiley   +1 more source

Impact of Electrode Distance in a Quasi-Uniform Model Electrode System on Lightning Impulse Breakdown Voltage in Various Insulating Liquids

open access: yesEnergies
This study presents findings on the influence of gap length distance on the lightning impulse breakdown voltage of three dielectric liquids of different chemical origins.
Wiktor Kunikowski   +5 more
doaj   +1 more source

Mechanism of Quasi‐Power‐Frequency Resonant Overvoltage Triggered by Multiple Lightning Strikes in High‐Voltage Alternating Current Systems Equipped With Shunt Reactor

open access: yesHigh Voltage, EarlyView.
ABSTRACT This paper investigates the generation mechanism of quasi‐power‐frequency resonant overvoltage triggered by multiple lightning strikes in high‐voltage alternating current (HVAC) systems equipped with shunt reactors. Based on field measurements from a 500 kV AC system, equivalent and simplified circuit models have been established to analyse ...
Tao Liang   +7 more
wiley   +1 more source

A study on the instantaneous and dynamic characteristics of impulse grounding resistance in grounding grids for artificially triggered lightning

open access: yesResults in Engineering
The impulse grounding resistance is a critical parameter for evaluating performance of lightning protection devices, and effectively reducing this resistance remains a major challenge in lightning protection or electrical engineering. While most previous
Juan Zhang   +6 more
doaj   +1 more source

Study on the Coupled Effects of High‐Speed Airflow and Charged Sand on Power‐Frequency Discharge Characteristics of Conductor–Tower Gaps in Strong Wind–Sand Environments

open access: yesHigh Voltage, EarlyView.
ABSTRACT Strong wind–sand weather in Xinjiang threatens power grid safety by increasing transmission line tripping risks. Existing studies focus on sand polarization but neglect the coupled influence of high‐speed airflow and charged sand on gap discharge characteristics.
Jianghai Geng   +8 more
wiley   +1 more source

Home - About - Disclaimer - Privacy