Results 91 to 100 of about 1,350 (191)

Long-term field measurement and characteristics of lightning-induced overvoltages on 10 kV distribution lines in high-altitude mountainous areas and optimization of insulation coordination

open access: yesResults in Engineering
Aiming at the lack of measured data on lightning overvoltages in operational distribution networks and the irrationality of insulation coordination based on standard lightning impulse waveforms, this paper carries out large-scale and long-term ...
Li Shao   +6 more
doaj   +1 more source

Evaluation of Step Response of Transient Recorders for Lightning Impulse

open access: yes, 2017
High voltage equipment will be subjected to several types of electrical stress during operation. A battery of factory tests is defined to ensure that the equipment will perform satisfactorily in service. One of the crucial tests is to apply a simulated lighting impulse as standardised to a double-exponential impulse with at front time of 1.2 µs (± 30 %)
Bergman, Anders   +2 more
openaire   +2 more sources

Characteristics and influence of lightning impulse discharge of zero-value insulator strings in heavy rainfall environment

open access: yes电力工程技术
Heavy rainfall can bridge the sheds of insulators on transmission lines, substations, and converter stations with continuous water columns, leading to electric field distortion.
Bingbing DONG, Yu QIAO, Xia YAO
doaj   +1 more source

Study on Transient Overvoltage and Surge Arrester Electrical Stresses in Offshore Wind Farms Under Multiple Lightning Strokes

open access: yesJournal of Marine Science and Engineering
Lightning strikes are a major cause of wind turbine (WT) damage, with approximately 80% of cloud-to-ground lightning strikes exhibiting a multi-stroke characteristic. Therefore, studying the transient overvoltages induced by multiple lightning strokes is
Jie Zhang   +7 more
doaj   +1 more source

Structural fault analysis of air-core reactors under lightning impulse

open access: yesZhejiang dianli
In ultra-high voltage (UHV) converter stations, the encapsulation of air-core reactors may deform under lightning impulse due to electromagnetic forces, which may induce structural faults and jeopardize the safe operation of power system. To address this
ZONG Wanli   +6 more
doaj   +1 more source

Effects of RTV coating on the electrical performance of polymer insulator under lightning impulse voltage condition. [PDF]

open access: yesPLoS One, 2017
Jamaludin FA   +5 more
europepmc   +1 more source

A Low Cost Real-Time Transient Recorder for High Voltage Systems. [PDF]

open access: yesSensors (Basel), 2023
Grebović S   +5 more
europepmc   +1 more source

Current Sensor with Optimized Linearity for Lightning Impulse Current Measurement. [PDF]

open access: yesSensors (Basel)
Li W   +7 more
europepmc   +1 more source

Home - About - Disclaimer - Privacy