Results 111 to 120 of about 314,581 (221)
ZnO varistors are widely used in the field of lightning protection. After being struck by lightning, ZnO varistors absorb heat, which can lead to temperature rise and even damage, posing a serious safety threat to electrical safety.
Li Chunying, Zhang Chunlong, Lv Qing
doaj +1 more source
8 p. transcript of an interview with Phillip Lightning conducted by Richard Lightning on April 11, 1975. Tape number IH-191, transcript disc 38.Tells stories from his father and grandfather of the signing of Treaty #6 and of Indian life before that time ...
Lightning, Richard, Lightning, Phillip
core +1 more source
Aiming at the lack of measured data on lightning overvoltages in operational distribution networks and the irrationality of insulation coordination based on standard lightning impulse waveforms, this paper carries out large-scale and long-term ...
Li Shao +6 more
doaj +1 more source
Experimental Study on Performance of SF6+N2 Mixed Gas Insulation
This paper designed and constructed a 126kV GIS partial discharge test platform, performed frequency breakdown tests and lighting impulse tests at temperature of -30~20℃to SF6/N2 gas mixture.
Lu Gang +6 more
doaj +1 more source
Photonic Voltage Transducer with Lightning Impulse Protection for Distributed Monitoring of MV Networks. [PDF]
Fusiek G, Niewczas P.
europepmc +1 more source
Single level impulse generator
Voltage Vs Time data taken from numerical computing environment after simulating single level impulse generator circuit. Peak voltage in this data-set achieved 4.2 Megavolts of voltage according to lightning properties published in various literature. It
Jana, S
core +2 more sources
Heavy rainfall can bridge the sheds of insulators on transmission lines, substations, and converter stations with continuous water columns, leading to electric field distortion.
Bingbing DONG, Yu QIAO, Xia YAO
doaj +1 more source
Lightning strikes are a major cause of wind turbine (WT) damage, with approximately 80% of cloud-to-ground lightning strikes exhibiting a multi-stroke characteristic. Therefore, studying the transient overvoltages induced by multiple lightning strokes is
Jie Zhang +7 more
doaj +1 more source
Evaluation of Step Response of Transient Recorders for Lightning Impulse
High voltage equipment will be subjected to several types of electrical stress during operation. A battery of factory tests is defined to ensure that the equipment will perform satisfactorily in service. One of the crucial tests is to apply a simulated lighting impulse as standardised to a double-exponential impulse with at front time of 1.2 µs (± 30 %)
Bergman, Anders +2 more
openaire +2 more sources
The effect of multiple lightning impulse on the electrical characteristics of transient voltage suppression diode as low voltage lightning protective device [PDF]
The behaviour and performance of surge protective devices such as transient voltage suppression (TVS) diode under the application of multiple lightning impulses are different from the single lightning impulse.
Azmi, Azralmukmin
core