Results 41 to 50 of about 1,321 (185)
Analysis of polarity characteristics of lightning attachment and protection to wind turbine blades
This study investigated the attachment of lightning polarity and protection to wind turbine blades. Positive-polarity switching impulse lightning exhibits a shielding effect on the wind turbine blade receptor, whereas negative-polarity switching impulse ...
Jeong-Min Woo, Sung-Man Kang, Munno Ju
doaj +1 more source
Breakdown process on rod–rod air gap under oscillating lightning impulse voltage
This study presents the discharge process on rod–rod electrodes under oscillating lightning impulse voltage. For this purpose, a measurement system has been developed to record the discharge currents at both rod electrodes simultaneously and to ...
Akif Gürlek
doaj +1 more source
ABSTRACT With increasing demands for fire safety and environmental friendliness, retrofilling transformers with alternative insulating liquids has become a growing trend. However, retrofilling power transformers remains uncertain, as more residual mineral oil compromises K‐class flame retardancy, and its impact on environmental performance has yet to ...
Zhenfu Tang +5 more
wiley +1 more source
Development of ± 550 kV DC GIS Basin Insulator
ABSTRACT The basin insulator is a core component of the insulation system for ± 550 kV gas‐insulated switchgear (GIS). This paper, using a finite element method for multi‐physics simulations of electric–thermal coupling, determines a geometry suitable for the industrial production of ± 550 kV GIS basin insulators.
Shaohua Cao +9 more
wiley +1 more source
Comparison of Dielectric Recovery After Arc Burning in SF6 Gas and Its Potential Alternatives
ABSTRACT Although sulphur hexafluoride (SF6) exhibits exceptional insulating properties, it is a potent greenhouse gas. Therefore, studying alternatives to SF6 is critical for developing environmentally friendly high‐voltage electrical equipment.
Ziqi Liu +4 more
wiley +1 more source
ABSTRACT This paper investigates the generation mechanism of quasi‐power‐frequency resonant overvoltage triggered by multiple lightning strikes in high‐voltage alternating current (HVAC) systems equipped with shunt reactors. Based on field measurements from a 500 kV AC system, equivalent and simplified circuit models have been established to analyse ...
Tao Liang +7 more
wiley +1 more source
This study presents findings on the influence of gap length distance on the lightning impulse breakdown voltage of three dielectric liquids of different chemical origins.
Wiktor Kunikowski +5 more
doaj +1 more source
ABSTRACT Strong wind–sand weather in Xinjiang threatens power grid safety by increasing transmission line tripping risks. Existing studies focus on sand polarization but neglect the coupled influence of high‐speed airflow and charged sand on gap discharge characteristics.
Jianghai Geng +8 more
wiley +1 more source
Application Status and Development Trends of DC Ice‐Melting Devices in China's Power Grid
This paper summarises the development history and engineering application status of DC ice‐melting devices (DCIMD) in China, analyses the principles, advantages, disadvantages and adaptability of mainstream topologies and discusses the key problems and corresponding improvement directions.
Ming Lei +6 more
wiley +1 more source
Protection against lightning is always a challenging job for the researcher. The consequences due to lightning on different building shapes needs a comprehensive knowledge in order to provide the information to the common man.
Ullah Irshad +4 more
doaj +1 more source