Results 61 to 70 of about 1,422 (223)
Comparison of Dielectric Recovery After Arc Burning in SF6 Gas and Its Potential Alternatives
ABSTRACT Although sulphur hexafluoride (SF6) exhibits exceptional insulating properties, it is a potent greenhouse gas. Therefore, studying alternatives to SF6 is critical for developing environmentally friendly high‐voltage electrical equipment.
Ziqi Liu +4 more
wiley +1 more source
ABSTRACT The stability analysis of Line Commutated Converter High Voltage Direct Current (LCC‐HVDC) is of considerable engineering importance. Establishing its analytical mathematical model helps to analyse stability and the factors that affect stability of the system.
Juanjuan Wang +6 more
wiley +1 more source
Breakage of Curved Copper Wires Caused by High Impulse Current of Lightning
In past studies, after thin straight copper wires of 0.1mmφ were exposed to an impulse current, their temperature rose; they melted according to the specific pre-arcing Joule integral in an adiabatic state. However, in this study, we confirmed that thick straight copper wires of 1mmφ and over it were broken in a solid state before melting The effect of
Hu, Xiaobo +2 more
openaire +1 more source
ABSTRACT This paper investigates the generation mechanism of quasi‐power‐frequency resonant overvoltage triggered by multiple lightning strikes in high‐voltage alternating current (HVAC) systems equipped with shunt reactors. Based on field measurements from a 500 kV AC system, equivalent and simplified circuit models have been established to analyse ...
Tao Liang +7 more
wiley +1 more source
ABSTRACT With the increasing voltage of ester oil‐filled transformers and their application in offshore wind power, developing high‐performance, fire‐resistant esters is crucial for enhancing transformer safety. Flash point, a key indicator of fire‐resistant performance for esters, is directly related to the molecular structures.
Jingwen Zhang +4 more
wiley +1 more source
Evaluation of electromagnetic fields on polluted polymer insulator under lightning impulse current [PDF]
This paper presents a simulation study of a polluted insulator under a direct lightning impulse current. The pollution condition was considered and divided into two cases which are partial and full pollution. Under those conditions, the electromagnetic profiles of the insulator were evaluated.
M. S. Abd-Rahman +5 more
openaire +1 more source
Application Status and Development Trends of DC Ice‐Melting Devices in China's Power Grid
This paper summarises the development history and engineering application status of DC ice‐melting devices (DCIMD) in China, analyses the principles, advantages, disadvantages and adaptability of mainstream topologies and discusses the key problems and corresponding improvement directions.
Ming Lei +6 more
wiley +1 more source
ABSTRACT The evolutionary study of human dispersal is a key topic in biological anthropology. However, recent research has revealed inconsistencies between molecular and anatomical data across different timescales and geographic regions. Despite increased interdisciplinary dialogue, these discordances are rarely analyzed in depth or interpreted for ...
Lumila Paula Menéndez, Sophie Veigl
wiley +1 more source
Influence of Pulse Interval on Soil Dispersion Characteristics under Continuous Impulse
Under continuous lightning strikes, the impulse dispersion characteristics of grounding devices more effectively indicate the effectiveness of tower grounding for lightning protection.
CAO, W. +4 more
doaj +1 more source
Lightning strikes are a major cause of wind turbine (WT) damage, with approximately 80% of cloud-to-ground lightning strikes exhibiting a multi-stroke characteristic. Therefore, studying the transient overvoltages induced by multiple lightning strokes is
Jie Zhang +7 more
doaj +1 more source