Results 1 to 10 of about 364 (176)
Some of the next articles are maybe not open access.
Overvoltages in photovoltaic systems induced by lightning strikes
2012 International Conference on Lightning Protection (ICLP), 2012The high number of photovoltaic systems raises questions regarding their operational security even under extremely weather conditions like thunderstorms. Therefore a simplified model of a photovoltaic system, consisting of typical arrangement of solar-panels, was investigated.
Z. Benesova +3 more
openaire +1 more source
Discussion Based on Small PABX Lightning Overvoltage
Advanced Materials Research, 2014Construction of large and medium-sized program-controlled switches be placed strictly in accordance with national standards Professional program-controlled switchboard in the room, general will not be affected by lightning overvoltage and harm of operating over voltage.
Guo Feng Sun, Yan Bai
openaire +1 more source
Lightning overvoltage protection for financial computerizing systems
Proceedings. Asia-Pacific Conference on Environmental Electromagnetics. CEEM'2000 (IEEE Cat. No.00EX402), 2002Financial systems are nowadays dependent on electronic data processing technology. One of the most frequent causes of failure in this highly sensitive system are overvoltages mostly caused by lightning. This paper describes how lightning electromagnetic pulse intrudes into computer information systems and causes system damage. Damage prevention is also
null Qui Chuan Rui, null Li Shui Guang
openaire +1 more source
Lightning overvoltages in wires within the buildings
IEEE 1991 International Symposium on Electromagnetic Compatibility, 2002Electromagnetic fields generated by lightning currents may cause damage or interference in the operation of electronic and electric systems. Particularly hazardous to equipment operating within a building is a direct lightning strike to the building or its vicinity.
openaire +1 more source
The Investigation of the Lightning Overvoltage of Secondary Cable of Substation
2020 IEEE International Conference on High Voltage Engineering and Application (ICHVE), 2020Lightning activities are easy to cause secondary equipment fault, affecting the safe and reliable operation of the substation. In this paper, the lightning current, tower, insulator string, overhead line, secondary cable, transformer, capacitor voltage transformer (CVT), earthing network and arrester are modeled by EMTP software.
Zhiyuan Zhang +9 more
openaire +1 more source
Non-contact miniature lightning overvoltage sensor
Ferroelectrics, 2019AbstractIn this paper, a miniature, high voltage-division ratio non-contact sensor system for measuring lightning overvoltage is designed and the high-voltage arm capacitance formed by the coupling...
Zhiguo Zhang +3 more
openaire +1 more source
Lightning and overvoltage protection of wind power farms
2011 International Symposium on Lightning Protection, 2011Wind power farms are prone to lightning due to their height, especially when installed off-shore. Very different voltage stresses are expected compared to three phase power systems. Test standards, technical specifications and application principles have been developed only recently on CENELEC level.
Bernhard Richter, Vincent Crevenat
openaire +1 more source
A system for experimental studies of lightning currents and overvoltages
2017 International Symposium on Lightning Protection (XIV SIPDA), 2017This paper presents the main features of a system for measuring lightning currents and induced voltages on an instrumented tower and an experimental line, respectively. The tower height is 70 m, and the line, which has a non-conventional configuration, is 800 m long.
Acacio Silva Neto +7 more
openaire +1 more source
Study of lightning overvoltage transients using ATP
2015 International Conference on Circuits, Power and Computing Technologies [ICCPCT-2015], 2015Rapid development of transmission and distribution network requires an in-depth research and development work for their proper operation. Protection of the components used in transmission and distribution substations is one of the most important factors which must be taken care of in a very efficient manner. In this paper the analysis of lightning over
T. Chatterjee, A. Mukherjee
openaire +1 more source

