Results 51 to 60 of about 364 (176)

Induced voltage at the closest pole on parallel line due to direct triggered lightning on 10 kV double circuit distribution line

open access: yesIET Generation, Transmission & Distribution, 2023
In 2019, triggered lightning was used to directly strike phase C of a 1.5 km, 10 kV double‐circuit distribution line in Guangzhou, China, with 2 flashes (13 return strokes) recorded.
Yating Zhao   +7 more
doaj   +1 more source

Research Progress on Electrical Insulation Under Superimposed Voltage With High‐Frequency Harmonics in New‐Type Power Systems

open access: yesHigh Voltage, Volume 11, Issue 5, Page 1265-1302, October 2026.
ABSTRACT A new‐type power system serves as a critical technical support for the integration of new energy, and its secure and stable operation is of great importance. However, the extensive utilisation of power electronic devices leads to power equipment insulation being subjected to electrical stresses of high‐frequency harmonics, which can easily ...
Shengtao Li   +4 more
wiley   +1 more source

Study on lightning overvoltage and commutation failure in UHV AC/DC hybrid system

open access: yesThe Journal of Engineering, 2019
Due to the high UHV AC/DC transmission line tower, the working voltage amplitude on the wire is large, causing lightning accidents. The paper first analyses the impact of lightning strike point on lightning overvoltage of 1000 kV UHV transformer ...
Shengwei Fang   +4 more
doaj   +1 more source

Advances in Polymeric Insulating Materials: Global Progress in These 10 Years

open access: yesHigh Voltage, Volume 11, Issue 5, Page 1213-1249, October 2026.
ABSTRACT This journal, High Voltage, celebrates its 10th anniversary in 2026. To commemorate this significant milestone, this comprehensive special review article showcases the latest global research progress and cutting‐edge advancements in polymeric insulating materials, a critical component that underpins high‐voltage systems and is vital to modern ...
Yoshimichi Ohki   +10 more
wiley   +1 more source

Three‐phase overvoltage at lightning strike point due to direct triggered lightning to the phase wire of 10 kV power distribution line

open access: yesIET Generation, Transmission & Distribution, 2022
This paper reports the observation results of three‐phase overvoltage at the lightning strike point of a 1.5 km, 10 kV power distribution line that was struck directly by rocket triggered lightning to its phase wire C.
Jianguo Wang   +7 more
doaj   +1 more source

Research Progress on Very Fast Transient Overvoltage in Gas Insulated Switchgear Substations

open access: yesHigh Voltage, Volume 11, Issue 5, Page 1153-1173, October 2026.
ABSTRACT Gas insulated switchgear (GIS) is widely used in substations across various voltage levels due to its compact structure and high reliability. However, GIS switching operations generate very fast electromagnetic transient processes, resulting in very fast transient overvoltage (VFTO) that threatens the insulation of primary equipment, and ...
Weijiang Chen   +7 more
wiley   +1 more source

Probe on Problems of Combined Overvoltage Protector in Lightning Protectio

open access: yesGong-kuang zidonghua, 2012
The paper analyzed accidents in application of combined overvoltage protector in a substation in Yangquan mining area of Shanxi province and a pumped storage power station in Hubei province. It introduced principle and working characteristics of combined
YI Xiao-fei   +3 more
doaj  

Long-term field measurement and characteristics of lightning-induced overvoltages on 10 kV distribution lines in high-altitude mountainous areas and optimization of insulation coordination

open access: yesResults in Engineering
Aiming at the lack of measured data on lightning overvoltages in operational distribution networks and the irrationality of insulation coordination based on standard lightning impulse waveforms, this paper carries out large-scale and long-term ...
Li Shao   +6 more
doaj   +1 more source

A Review of the Functional Properties of Ester Liquids for Power Transformers

open access: yesHigh Voltage, Volume 11, Issue 5, Page 1376-1398, October 2026.
ABSTRACT Ester liquids have become viable alternatives to conventional mineral oils for power transformer applications, mainly driven by increasing demands for enhanced fire safety and environmental sustainability. This paper reviews the historical development and functional properties of synthetic and natural ester liquids, with particular emphasis on
Qiang Liu   +10 more
wiley   +1 more source

Research on lightning impulse simulation method and protection technology of a traction power supply system

open access: yes机车电传动, 2022
The traction power supply system will have high amplitude transient overvoltage after lightning stroke, which will affect the stable operation of railway transportation system.
XIE Xuefang
doaj  

Home - About - Disclaimer - Privacy