This paper deals with the evaluation of lightning-induced overvoltages in a typical light-rail DC traction overhead power line. In particular, results provided by a new ad-hoc full-wave formulation are compared with those obtained by classical field ...
PAOLONE, MARIO +6 more
core
Lightning-originated overvoltages in a multi-circuit HV-MV line
The analysis of lightning-originated flashovers occurring on a multi-circuit high voltage (HV)-medium voltage (MV) overhead line, from indirect and direct lightning, is presented in the paper.
Piantini A. +6 more
core +1 more source
Transformation of Transient Overvoltages by Inductive Voltage Transformers. [PDF]
Kaczmarek M, Brodecki D.
europepmc +1 more source
Acoustic Noise-Based Detection of Ferroresonance Events in Isolated Neutral Power Systems with Inductive Voltage Transformers. [PDF]
Martinez R +7 more
europepmc +1 more source
Lightning Overvoltages on Medium Voltage Lines with Covered Conductors and Overhead Cables
Prenaponske pojave atmosferskog porijekla predstavljaju značajan izvor kvarova na nadzemnim vodovima. U ovom radu analizirani su atmosferski prenaponi na nadzemnim srednjenaponskim vodovima s izoliranim vodičima i nadzemnim srednjenaponskim kabelskim ...
Babić, Boris
core
Lightning Induced Overvoltages Caused by Non-Vertical Lightning and Earth Current Behavior [PDF]
RÉSUMÉ: Les surtensions induites par la foudre deviennent un sujet important dans le domaine des réseaux de distribution. Une évaluation précise des tensions induites est très essentielle pour la protection contre la foudre.
Natsui, Masashi
core
ANALYSIS OF BACK FLASHOVER CAUSED BY LIGHTNING INDUCED OVERVOLTAGES
U ovom radu analiziran cijeli proces nastajanja atmosferskih prenapona. Atmosferske prenapone uzrokuje atmosfersko pražnjenje električnog naboja , iz toga razloga u radu je taj proces objašnjen od samog nastajanja atmosferskih električnih naboja, pa ...
Tomić, Drago
core
--The aim of the paper is to analyze overvoltages in overhead distribution lines induced by nearby lightning return stroke currents taking into account also the conductive coupling between the lightning current injected into the soil and the line’s ...
F. Napolitano +10 more
core +1 more source
Electrical Performance of Polymer-Insulated Rail Brackets of DC Transit Subjected to Lightning Induced Overvoltage. [PDF]
Abd Rahman FA +3 more
europepmc +1 more source
The Behavior of Polyurethane Foam-Filled Glass-Fiber-Reinforced Polymer Crossarm Subjected to Lightning Transient Voltage. [PDF]
Abd Rahman MS +6 more
europepmc +1 more source