Results 181 to 190 of about 156,674 (316)
X‐ray computed tomography reveals how process‐induced defects evolve from green to sintered states in Fused Filament Fabrication (FFF)‐manufactured 17‐4PH stainless steel. Internal porosity, weakest cross‐sections, and fracture locations show strong correlation with tensile performance, demonstrating the potential of computed tomography (CT)‐based ...
György Ledniczky +3 more
wiley +1 more source
Individual, High-Precision 3D Mandibular Model for Finite Element Analysis of Three-Unit Bridges: A Biomechanical Pilot Study. [PDF]
Pelsőczi-Kovács I +3 more
europepmc +1 more source
Design and Analysis of Compression–Torsion Coupling Metamaterials Using the Golden Section Method
A novel compression–torsion metamaterial is engineered using inclined rods and symmetry breaking. To optimize its torsional performance, the golden section method is employed. The mechanical response of the metamaterial is validated through both numerical analysis and experimental validation.
Amirhossein Hassani, Sara Bagherifard
wiley +1 more source
Stresses and fluid flow in lamina cribrosa through anisotropic poroelasticity. [PDF]
Cavuoto R +7 more
europepmc +1 more source
Experiments and thermophysical simulations were conducted to investigate the electron beam powder bed fusion electron beam (PBF‐EB/M) process for the γ′‐strengthened nickel‐based superalloy Inconel 738LC. The results demonstrate the impact of process‐induced microstructural variations on high‐temperature mechanical behavior, providing a basis for ...
Jan Niklas Petenati +11 more
wiley +1 more source
In the finite element modelling of structural frames, external loads such as wind loads, dead loads and imposed loads usually act along the elements rather than at the nodes only.
Iu, C.K., Bradford, M.A.
core
The Effect of Variable Resistance Training on Post-Activation Performance Enhancement: A Systematic Review and Three-Level Meta-analysis. [PDF]
Yan Z, Lin S, Wu J, Yi X, Liu J, Liu R.
europepmc +1 more source
Functionally graded metal–ceramic femoral stems are engineered through continuous UMAT‐based stiffness tailoring, eliminating discrete material interfaces while enhancing biomechanical compatibility. Low‐index power‐law gradation optimizes load transfer, reduces stress shielding, and controls implant–bone micromotion, highlighting a materials‐design ...
Rihem Nouira, Sameh Elleuch, Hanen Jrad
wiley +1 more source
A General Tensorial Formulation of Acoustoelasticity and Its Representation in Cylindrical Coordinates. [PDF]
Ma Y, Xu C, Yang S, Chen C.
europepmc +1 more source
Enhancing Low‐Temperature Performance of Sodium‐Ion Batteries via Anion‐Solvent Interactions
DOL is introduced into electrolytes as a co‐solvent, increasing slat solubility, ion conductivity, and the de‐solvent process, and forming an anion‐rich solvent shell due to its high interaction with anion. With the above virtues, the batteries using this electrolyte exhibit excellent cycling stability at low temperatures. Abstract Sodium‐ion batteries
Cheng Zheng +7 more
wiley +1 more source

