Results 71 to 80 of about 37,303 (242)
Multifunctional Eutectic Mixtures Enable Integrated Recovery of U, Pu, and Sr From Nuclear Waste
Advanced Science, EarlyView.A novel class of multifunctional eutectic mixtures, crafted from crown ether and organophosphorus molecules, achieves highly efficient, simultaneous recovery of uranium, plutonium, and strontium from nuclear waste. The material operates via a dual “coordination‐encapsulation” mechanism within self‐assembled reverse‐micelle structures, offering a ...Yifan Wang, Yanjun Lv, Qilong Tang, Huaixin Hao, Jianfeng Jia, Gang Ye, Jing Chen, Chao Xu, Zhipeng Wang +8 morewiley +1 more sourceScintillating properties of frozen new liquid scintillators [PDF]
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1999 Abstract The light emission from scintillators which are liquid at room temperature was studied in the interval between +20°C and −120°C where the phase transition from liquid to solid takes place. The light yield measured at −120°C is about twice as much as that observed at +20°C.G. I. Britvich, F. Galeazzi, S. V. Golovkin, G. Martellotti, A. M. Medvedkov, PENSO, Gianni, A. S. Solovjev, V. G. Vasil'Chenko +7 moreopenaire +2 more sourcesStructural and Compositional Effects on the Scintillation Properties of Fast Emitting Metal‐Organic Frameworks
Advanced Science, EarlyView.The crystalline structure, the atomic numbers of the constituent elementsand the size of MOF crystals each influence their photoluminescence and scintillation properties in distinct ways. Together, these factors provide valuable guidelines for designing systems with optimized performance and tunable timing characteristics, arising from the synergistic ...Francesca Cova, Jacopo Perego, Biplab Joarder, Nobuhiro Yanai, Anna Vedda, Silvia Bracco, Angiolina Comotti, Angelo Monguzzi, Irene Villa +8 morewiley +1 more sourceThe Double Chooz antineutrino detectors
European Physical Journal C: Particles and Fields, 2022 This article describes the setup and performance of the near and far detectors in the Double Chooz experiment. The electron antineutrinos of the Chooz nuclear power plant were measured in two identically designed detectors with different average ...H. de Kerret, Y. Abe, C. Aberle, T. Abrahão, J. M. Ahijado, T. Akiri, J. M. Alarcón, J. Alba, H. Almazan, J. C. dos Anjos, S. Appel, F. Ardellier, I. Barabanov, J. C. Barriere, E. Baussan, A. Baxter, I. Bekman, M. Bergevin, A. Bernstein, W. Bertoli, T. J. C. Bezerra, L. Bezrukov, C. Blanco, N. Bleurvacq, E. Blucher, H. Bonet, M. Bongrand, N. S Bowden, T. Brugière, C. Buck, M. Buizza Avanzini, J. Busenitz, A. Cabrera, E. Caden, E. Calvo, L. Camilleri, R. Carr, S. Cazaux, J. M. Cela, M. Cerrada, P. J. Chang, P. Charon, E. Chauveau, P. Chimenti, T. Classen, A. P. Collin, E. Conover, J. M Conrad, S. Cormon, O. Corpace, B. Courty, J. I. Crespo-Anadón, M. Cribier, K. Crum, S. Cuadrado, A. Cucoanes, M. D’Agostino, E. Damon, J. V. Dawson, S. Dazeley, M. Dierckxsens, D. Dietrich, Z. Djurcic, F. Dorigo, M. Dracos, V. Durand, Y. Efremeko, M. Elnimr, A. Etenko, E. Falk, M. Fallot, M. Fechner, J. Felde, S. M. Fernandes, C. Fernández-Bedoya, D. Francia, D. Franco, V. Fischer, A. J. Franke, M. Franke, H. Furuta, F. Garcia, J. Garcia, I. Gil-Botella, L. Giot, A. Givaudan, M. Göger-Neff, H. Gomez, L. F. G. Gonzalez, L. Goodenough, M. C. Goodman, J. Goon, B. Gramlich, D. Greiner, A. Guertin, B. Guillon, S. M. Habib, Y. Haddad, T. Hara, F. X. Hartmann, J. Hartnell, J. Haser, A. Hatzikoutelis, D. Hellwig, S. Hervé, R. Hofacker, G. Horton-Smith, A. Hourlier, M. Ishitsuka, K. Jänner, S. Jiménez, J. Jochum, C. Jollet, F. Kaether, K. Kale, L. Kalousis, Y. Kamyshkov, M. Kaneda, D. M. Kaplan, M. Karakac, T. Kawasaki, E. Kemp, Y. Kibe, T. Kirchner, T. Konno, D. Kryn, T. Kutter, M. Kuze, T. Lachenmaier, C. E. Lane, C. Langbrandtner, T. Lasserre, C. Lastoria, L. Latron, C. Leonardo, A. Letourneau, D. Lhuillier, H. P. Lima, M. Lindner, J. M. López-Castaño, J. M. LoSecco, B. Lubsandorzhiev, S. Lucht, J. Maeda, C. N. Maesano, C. Mariani, J. Maricic, F. Marie, J. J. Martinez, J. Martino, T. Matsubara, D. McKee, F. Meigner, G. Mention, A. Meregaglia, J. P. Meyer, T. Miletic, R. Milincic, J. F. Millot, A. Minotti, V. Mirones, H. Miyata, Th. A. Mueller, Y. Nagasaka, K. Nakajima, D. Navas-Nicolás, Y. Nikitenko, P. Novella, L. Oberauer, M. Obolensky, A. Onillon, A. Oralbaev, I. Ostrovskiy, C. Palomares, S. J. M. Peeters, I. M. Pepe, S. Perasso, P. Perrin, P. Pfahler, A. Porta, G. Pronost, J. C. Puras, R. Quéval, J. L. Ramirez, J. Reichenbacher, B. Reinhold, M. Reissfelder, A. Remoto, D. Reyna, I. Rodriguez, M. Röhling, R. Roncin, N. Rudolf, B. Rybolt, Y. Sakamoto, R. Santorelli, F. Sato, U. Schwan, S. Schönert, S. Schoppmann, L. Scola, M. Settimo, M. A. Shaevitz, R. Sharankova, V. Sibille, J.-L. Sida, V. Sinev, D. Shrestha, M. Skorokhvatov, P. Soldin, J. Spitz, A. Stahl, I. Stancu, P. Starzynski, M. R. Stock, L. F. F. Stokes, M. Strait, A. Stüken, F. Suekane, S. Sukhotin, T. Sumiyoshi, Y. Sun, Z. Sun, R. Svoboda, H. Tabata, N. Tamura, K. Terao, A. Tonazzo, F. Toral, M. Toups, H. Trinh Thi, F. Valdivia, G. Valdiviesso, N. Vassilopoulos, A. Verdugo, C. Veyssiere, B. Viaud, D. Vignaud, M. Vivier, S. Wagner, C. Wiebusch, B. White, L. Winslow, M. Worcester, M. Wurm, J. Wurtz, G. Yang, J. Yáñez, F. Yermia, K. Zbiri +249 moredoaj +1 more sourceResponse of an Infant With Presumed Multiple Acyl‐CoA Dehydrogenase Deficiency (MADD) to Ketone Supplementation
American Journal of Medical Genetics Part A, EarlyView.ABSTRACT
Multiple Acyl‐CoA Dehydrogenase Deficiency (MADD) is an autosomal recessive inborn error of metabolism caused by biallelic pathogenic variants in one of three known genes: ETFA, ETFB, and ETFDH. It can cause multisystem dysfunction, including cardiomyopathy in severe cases.Yutaka Furuta, Kaitlyn N. Bloom, Jerry Vockley, Angela R. Grochowsky, Neena S. Agrawal, Ellen W. Strickler, Natalie N. Owen, Erica T. Gray, B. Lakshitha A. Perera, Eric R. Gamazon, Lynette C. Rives, Hua‐Chang Chen, Qi Liu, Rizwan Hamid, Joy D. Cogan, John A. Phillips III, Thomas A. Cassini, Bryce A. Schuler +17 morewiley +1 more sourceAging behavior and lifetime prediction of PMMA under tensile stress and liquid scintillator conditions
Advanced Industrial and Engineering Polymer Research, 2019 The aging behaviors of PMMA in liquid scintillator at different temperatures of 30 °C, 40 °C, 50 °C and 55 °C under static tensile stress were experimentally investigated with dynamic mechanical analysis (DMA) and differential scanning calorimetry (DSC), Wenhua Yin, Zeyu Xie, Yuming Yin, Jun Yi, Xiaodan Liu, Huiqin Wu, Shuang Wang, Yufang Xie, Yunong Yang +8 moredoaj +1 more sourceHalide perovskites in wide‐spectrum photodetection
Bulletin of the Korean Chemical Society, EarlyView.Recent advances in perovskite‐based photodetectors (PPDs), phototransistors, and photoconductors are technically discussed in this review. Moreover, the mechanism behind different harvesting processes in perovskite following the energy of photons is explained, where the gamma or x‐rays are ionizing.Somayeh Gholipour, Reza Rahighi, Mohammad Panahi, Muhammad Naufal Lintangpradipto, Reza Ghayoor, Michael Saliba +5 morewiley +1 more sourceAdvances in Human Mass Balance Studies: An IQ Consortium Perspective on Current Practices and Emerging Trends
Clinical Pharmacology &Therapeutics, EarlyView.Human radiolabeled mass balance studies are crucial for comprehensively characterizing the absorption, distribution, metabolism, and excretion (ADME) of investigational drugs, providing essential data for drug development, regulatory evaluation, and product labeling.Jason Boer, Ellen Cannady, Filip Cuyckens, Ulrike Glaenzel, Camille Granvil, Felix Huth, Alexander D. James, Wenying Li, Céline Veau, Graeme Young, Qin Yue, Gregory S. Walker, Upendra A. Argikar, Jonathan N. Bauman, Cathy Cantalloube, Yu‐Luan Chen, Ping Kang, Patricia Moliner, Mette L. Pedersen, Isabel Piel, Simone Schadt, Hanno Schieferstein, Julia Suchomel, Shuai Wang, S. Cyrus Khojasteh +24 morewiley +1 more source