Results 1 to 10 of about 112,374 (163)

Influence of connection configuration on the punching resistance of CFST column–RC slab systems under eccentric loading [PDF]

open access: yesScientific Reports
This study investigates the punching shear behaviour and failure mechanisms of concrete-filled steel tube (CFST) column reinforced concrete (RC) slab connections subjected to eccentric loading through an integrated experimental and numerical approach ...
Mohamed Ghalla   +5 more
doaj   +2 more sources

Load–impulse characterization for steel connection

open access: yesInternational Journal of Impact Engineering, 2009
Abstract Abnormal loading generated by blast or impact may cause local damage in a building that may evolve to affect the whole structural system. Therefore, structures have to be designed to prevent such disproportional consequences. Connection is an important contributor to ductility and robustness of the structural steel systems in mitigating such
Center for Infrastructure Protection and Physical Security, University of Florida NE Waldo Road, Building No.1604, Gainesville, FL 32609, USA ( host institution )   +2 more
exaly   +3 more sources

Evaluation of the response of BFP and WFP connections under the blast loading [PDF]

open access: yesJournal of Structural and Construction Engineering, 2021
one of the most important structural members that greatly affects the overall performance of the structure is the beam-to-column connection. Undesirable performance and failure of these connections can lead to local failure in the first step, and in the ...
SayyidAhmad Hosseini, Mirmohsen Hosseini
doaj   +1 more source

The Hysteresis Behavior of Steel Beam–Column Joint with the Load Bearing-Energy Dissipation Connection for Converter Station Building

open access: yesBuildings
Prefabricated converter station building has been gradually applied in the field of power engineering construction due to the advantages of standardized design, high construction efficiency, and quality control.
Xian Gao   +3 more
doaj   +3 more sources

Application of the Vortex Search Algorithm to the Phase-Balancing Problem in Distribution Systems

open access: yesEnergies, 2021
This article discusses the problem of minimizing power loss in unbalanced distribution systems through phase-balancing. This problem is represented by a mixed-integer nonlinear-programming mathematical model, which is solved by applying a discretely ...
Brandon Cortés-Caicedo   +4 more
doaj   +1 more source

Peer Connection Classifier Method for Load Balancing Technique

open access: yesInternational Journal of Electrical, Energy and Power System Engineering, 2021
A large number of requests for internet access causes a long response time resulting in an overload problem. This problem occurs in offices that provide public services such as the Soeman HS Regional Library and Archives Office in Riau Province.
Ery Safrianti
doaj   +1 more source

Service Load Analysis of Timber Construction Truss [PDF]

open access: yesMATEC Web of Conferences, 2022
This study aims to determine the service load capacity of existing truss construction using the wood material. Analysis and calculations were performed on tensile members, compression members,connection, and deflections that occur using the standard SNI ...
Doloksaribu Budi, Utary Chitra
doaj   +1 more source

Osteocytes and mechanical loading: The Wnt connection [PDF]

open access: yesOrthodontics & Craniofacial Research, 2019
Structured AbstractBone adapts to the mechanical forces that it experiences. Orthodontic tooth movement harnesses the cell‐ and tissue‐level properties of mechanotransduction to achieve alignment and reorganization of the dentition. However, the mechanisms of action that permit bone resorption and formation in response to loads placed on the teeth are ...
Whitney A. Bullock   +2 more
openaire   +2 more sources

Experimental on Attached Lifting Scaffolds Considering the Effect of Protective Panel

open access: yesTaiyuan Ligong Daxue xuebao, 2022
Attached lifting scaffold is a new type of scaffold developed rapidly in the early 21st century. In order to clarify its bearing performance and further reduce its self-weight, static loading tests were carried out on six frame sub-structures with ...
Yuhang WANG   +3 more
doaj   +1 more source

Tests of the embedded laminated glass connection under short-term tensile and eccentric shear loads

open access: yesChallenging Glass Conference Proceedings, 2020
The embedded laminated glass connection belongs to the group of the most widely used ways of the glass components connecting. As it becomes common to use glass as a material for load-bearing elements, the connection must be able to bear stresses arising ...
Michaela Zdražilová   +2 more
doaj   +1 more source

Home - About - Disclaimer - Privacy