Results 1 to 10 of about 1,221,101 (305)

Reliable in vitro method for the evaluation of the primary stability and load transfer of transfemoral prostheses for osseointegrated implantation [PDF]

open access: yesFrontiers in Bioengineering and Biotechnology
Osseointegrated transfemoral prostheses experience aseptic complications with an incidence between 3% and 30%. The main aseptic risks are implant loosening, adverse bone remodeling, and post-operative periprosthetic fractures.
Giulia Galteri   +6 more
doaj   +2 more sources

Double-Drum Test Bench for Variable Load Transfer Simulation by Electromechanical Inertia Compensation [PDF]

open access: yesSensors, 2019
To improve the accuracy and actual road equivalence of vehicle performance testing using test benches, a double-drum test bench that meets the test requirements of vehicle control system prototypes and in-use vehicles was designed.
Zhichao Xing   +5 more
doaj   +2 more sources

The Behavior of a Thread-Bar Grouted Anchor in Soils from Local Strain Monitoring

open access: yesApplied Sciences, 2020
International standards discourage the use of grouted anchors with a fixed length exceeding 10 m. However, grouted anchors with a fixed length between 10 and 20 m are frequently used in Italy to transfer high loads to ground with poor geotechnical ...
Paolo Ruggeri   +2 more
doaj   +1 more source

Strengthening Mechanisms of Aluminum Matrix Nanocomposites Reinforced with CNTs Produced by Powder Metallurgy

open access: yesMetals, 2021
The present work aims to investigate the strengthening mechanisms in aluminum matrix nanocomposites reinforced by carbon nanotubes (CNTs). A classical powder metallurgy route produced Al-CNT nanocomposites using ultrasonication and ball milling as ...
Íris Carneiro   +2 more
doaj   +1 more source

Load transfer on instrumented prestressed ground anchors in sandy soil

open access: yesRevista IBRACON de Estruturas e Materiais, 2021
: This study evaluates load variations in instrumented prestressed ground anchors installed in a bored pile retaining wall system in sandy soil. Data were collected from instrumentation assembled in the bonded length of three anchors, which were ...
Alex Micael Dantas de Sousa   +3 more
doaj   +1 more source

Experimental evaluation of load transfer efficiency of non-dowelled concrete pavements

open access: yesGrađevinar, 2022
Generally, joint performance in concrete pavements is evaluated in laboratory by applying dynamic loads that require large scale experimental setups. In order to propose a simplified laboratory test, a comprehensive literary review of the fundamentals of
Mauricio Pradena   +2 more
doaj   +1 more source

Trends of mechanical consequences and modeling of a fibrous membrane around femoral hip prostheses [PDF]

open access: yes, 1990
In the present study, the effects of a fibrous membrane between cement and bone in a femoral total hip replacement were investigated. The study involved the problem of modeling this fibrous membrane in finite-element analyses, and its global consequences
Brand   +28 more
core   +9 more sources

Laboratory Characterization of The Load Transfer-Crack Width Relation for Innovative Short Concrete Slabs Pavements

open access: yesThe Baltic Journal of Road and Bridge Engineering, 2020
Aggregate interlock is the dominant load transfer mechanism in non-dowelled Jointed Plain Concrete Pavements, as the innovative short concrete slabs.
Mauricio Pradena   +2 more
doaj   +1 more source

Effect of Thoracic Connective Lesion on Inter-Leg Coordination in Freely Walking Stick Insects

open access: yesFrontiers in Bioengineering and Biotechnology, 2021
Multi-legged locomotion requires appropriate coordination of all legs with coincident ground contact. Whereas behaviourally derived coordination rules can adequately describe many aspects of inter-leg coordination, the neural mechanisms underlying these ...
Miriam Niemeier   +3 more
doaj   +1 more source

Significant strengthening effect in few-layered MXene-reinforced Al matrix composites

open access: yesMaterials Research Letters, 2021
In this study, Al matrix composites (AMCs) reinforced with few-layered MXene (FLM) were fabricated for the first time using self-assembly protocol and powder metallurgy.
Weiwei Zhou   +3 more
doaj   +1 more source

Home - About - Disclaimer - Privacy