Results 41 to 50 of about 365,638 (279)

Peri-implant stress distribution assessment of various attachment systems for implant supported overdenture prosthesis by finite element analysis – A systematic review

open access: yesJournal of Oral Biology and Craniofacial Research, 2022
Background: Various attachments like ball, bar-clip, magnetic attachments are used in implant supported overdentures. Finite Element Analysis (FEA) a newly innovated technology has been used in dental implantology to evaluate stress distribution patterns.
Bappaditya Bhattacharjee   +4 more
doaj   +1 more source

In vitro study of the effect of implant position and attachment type on stress distribution of implant-assisted removable partial dentures

open access: yesJournal of Dental Sciences, 2022
Background/purpose: Implant assisted removable partial dentures (IARPDs) improved biomechanical behavior of removable partial dentures (RPDs), but information of the effect of attachment type and implant position is limited.
Sai Tun Naing   +7 more
doaj   +1 more source

Effect of Abutments Design on Wear of Locator Attachments in Effect of Abutments Design on Wear of Locator Attachments in Implant Retained Mandibular Overdenture

open access: yesFuture Dental Journal, 2022
Purpose: The aim of this study is to compare the effect of abutments design on wear behavior of Locator attachments in implant-retained mandibular overdenture. Materials and Methods: Two epoxy models representing an edentulous mandible were used, two implants were placed in each model.
Mahmoud Fayed   +2 more
openaire   +1 more source

An identifier-locator approach to host multihoming [PDF]

open access: yes, 2014
We are grateful to Cisco for their University Research Programmme (URP) in supporting this work. Date of Acceptance: 24/01/2014Host multihoming allows individual hosts to be multiply connected to the network, e.g.
Bhatti, S. N.   +4 more
core   +1 more source

Location of attachment moiety on Mycoplasma pneumoniae.

open access: yesThe Yale journal of biology and medicine, 1983
Mycoplasma pneumoniae initiates infection in the human host by attachment to respiratory epithelium. The organism attaches by a specialized terminal structure. Monoclonal antibodies to an organism surface protein (P1) inhibited attachment to respiratory epithelium and were localized to the tip structure by a ferritin antibody label.
A M, Collier, P C, Hu, W A, Clyde
openaire   +2 more sources

PEMBUATAN PROTESA IMPLANT OVERDENTURE DENGAN DUKUNGAN LOCATOR ATTACHMENT (Procedure Laboratory) [PDF]

open access: yes, 2017
pada penghilangan rasa sakit. Maka saat ini cenderung menitikberatkan pada pemenuhan fungsi kunyah dan bicara, namun juga tentang stabilitas dan estetik.Implant overdenture secara komersial disebut sistem attachment yang menghubungkan implant dan ...
SEALVIA DIAN PUSPITA SARI, 151410513023
core   +1 more source

In vitro retention capacity of two overdenture attachment systems: Locator® and Equator® [PDF]

open access: yes, 2018
Background: It is necessary to know the in vitro behavior of different attachment systems to be used clinically. The evolution of retention capacity over 10 years (14,600 insertion/de-insertion cycles) was determined in vitro, evaluating two overdenture ...
Mínguez Tomás, Nieves   +4 more
core   +1 more source

PERBEDAAN KEKUATAN RETENSI ATTACHMENT SYSTEM ANTARA LOCATOR DAN O-RING PADA INTERPREMOLAR IMPLANT OVERDENTURE Penelitian Quasi Eksperimental (In vitro) [PDF]

open access: yes, 2019
Attachment system merupakan suatu alat mekanik yang berfungsi sebagai retensi, fiksasi dan stabilisasi protesa. Attachment system bertujuan untuk menghubungkan implant dengan gigi tiruan diatasnya. Penggunaan attachment system ini mampu menambah kekuatan
Safitri, Dyanti Azifah
core   +1 more source

One-Year Multicenter Randomised Controlled Trial Comparing OT Equator® and Locator Attachments to Retain an Early Loaded Implant Overdenture on Two Implants

open access: yesInternational Journal of Biomaterials, 2023
This investigation aimed to compare the effectiveness of the OT Equator® (Rhein, Bologna, Italy) and the Locator attachment systems used to retain early loaded implant-retained overdentures.
Marco Tallarico   +12 more
doaj   +1 more source

Stress Generated in Bone with Different Configurations of Implants and Attachments in a Mandibular Implant-retained Overdenture: A Finite Element Analysis [PDF]

open access: yesInternational Journal of Prosthodontics and Restorative Dentistry, 2023
Purpose: The purpose of this finite element analysis (FEA) study was to investigate stress distribution in bone distal to the implant by varying the attachments, implant configurations, and biomaterials in a mandibular implant-retained overdenture (IRO).
Abeer Wali   +5 more
doaj   +1 more source

Home - About - Disclaimer - Privacy