Results 191 to 200 of about 848 (238)
ANALYTICAL MODEL AND CALCULATIONS OF HYPOTHETICAL LOSS-OF-COOLANT ACCIDENT.
openaire +2 more sources
Some of the next articles are maybe not open access.
Related searches:
Related searches:
Detecting loss-of-coolant accidents without accident-specific data
Progress in Nuclear Energy, 2020Abstract This paper develops an automated fault detection tool to detect very small LOCAs in pressurized water reactors that would be difficult for operators to detect manually. One of the primary challenges with previous automated fault detection methods, which are data-driven, is that they require data from LOCAs; however, it may be difficult to ...
Jacob A. Farber, Daniel G. Cole
openaire +1 more source
BEST ESTIMATE THERMAL-HYDRAULIC ANALYSIS OF LOSS OF COOLANT ACCIDENTS
Proceeding of Advances in Heat Transfer Engineering, 2023Analysis of loss of coolant accidents is one of the most important issues in the Design Basis Accident assessment. Since a number of LOCAs is defined in terms of break size and location of the break, the variety of analyses for postulated accidents should be performed.
Kaliatka, Algirdas +2 more
openaire +2 more sources
Preliminary analysis of loss-of-coolant accident in Fukushima nuclear accident
AIP Conference Proceedings, 2012Loss-of-Coolant Accident (LOCA) in Boiling Water Reactor (BWR) especially on Fukushima Nuclear Accident will be discussed in this paper. The Tohoku earthquake triggered the shutdown of nuclear power reactors at Fukushima Nuclear Power station. Though shutdown process has been completely performed, cooling process, at much smaller level than in normal ...
Zaki Su’ud, Rio Anshari
openaire +1 more source
The AEC and the Loss of Coolant Accident
Nature, 1973Professor Wilson gives the background to the concern being expressed about the risks associated with the possible loss of coolant from a nuclear reactor.
openaire +1 more source
Analysis for loss of coolant accident in a fusion reactor
Fusion Engineering and Design, 1996Active cooling components have to be employed in the divertor of a fusion reactor to handle the large power flow from the core plasma. An extremely large thermal stress and electromagnetic force acting on these components may cause cracking of the cooling pipe.
T. Hino, Y. Hirohata, T. Yamashina
openaire +1 more source
Heat-transfer analysis in loss-of-coolant accidents
Nuclear Engineering and Design, 1968Abstract A computer program has been written for the comprehensive analysis of core-pressure-vessel heat transfer during a loss-of-coolant accident. The program, NURLOC-1.0, is based upon a generalized procedure for numerically solving the two-dimensional heat-conduction equation over multi-connected regions with various complicating factors specific
Craig T. Walters +2 more
openaire +1 more source
Analysis of MH-1A Loss of Coolant Accident
1972Abstract : Analyses of a postulated loss of coolant accident (LOCA) for the MH- 1A Nuclear Power Plant are presented for large and intermediate size breaks in the primary system. Methods and assumptions consistent with AEC Interim Acceptance Criteria were used in evaluating the performance of the Emergency Core Cooling System (ECCS). The computer codes
Paul M. Terpolilli +3 more
openaire +1 more source
Loss of Coolant Accident and Loss of Flow Accident Analysis of the ARIES-AT Design
Fusion Technology, 2001Loss of coolant accident (LOCA) and loss of flow accident (LOFA) analysis is performed for ARIES-AT, an advanced fusion power plant design (1000 MWe). ARIES-AT employs a high performance, high temperature blanket system. It uses the high temperature SiC/SiC for structural material and LiPb for coolant-breeder.
E. A. Mogahed +4 more
openaire +1 more source
BWR loss of coolant accident simulation by means of RELAP5
Nuclear Engineering and Design, 2016Abstract Application of best estimate codes and methodologies for LOCA simulation can provide the high level of details of the real plant response necessary to assess the adequacy of an emergency core cooling system. The current KKM RELAP5 model developed for the KKM plant (Muhleberg nuclear power station) has been demonstrated to be valid for ...
K. Nikitin +4 more
openaire +1 more source