Results 71 to 80 of about 29,048 (129)

New Snubbers with Energy Recovery into a Local Power Supply

open access: yes, 2008
- The general attributes governing the design of Local Power Supplies (LPS) circuits that are piggybacked on a lossless turn off snubbers are highlighted and analyzed. Based on the proposed general principles, new LPS circuits are presented.
Sam Ben-yaakov   +2 more
core  

An Interleaved Step-up DC-DC Converter with Lossless Snubber

open access: yesMajlesi Journal of Electrical Engineering
In this paper, an interleaved step-up converter with two lossless snubbers is introduced, where the snubbers ensure zero-current switching for the main switches, eliminating the need for extra switches. Additionally, the energy from the snubbers is transferred to the output.
Arman Hovsep   +3 more
openaire   +1 more source

Floating Step-Down Converter With a Novel Lossless Snubber

open access: yesApplied Sciences (Switzerland)
In this research, a step-down converter with a lossless snubber is proposed, and its output is floating; therefore, it can be applied to LED driving applications.
Jenn-Jong Shieh, Kuo-Ing Hwu
exaly   +3 more sources

Novel Passive Lossless Turn-On Snubber for Voltage Source Inverters

open access: yesIEEE Transactions on Power Electronics, 1997
A novel passive lossless turn-on snubber with a soft-clamped turn-off snubber circuit for voltage source inverters is proposed. The energy trapped in the snubber is recovered into the dc supply and load without any active devices, associated control ...
Xiangning He, S J Finney, B W Williams
exaly   +3 more sources

A Method for CM EMI Suppression on PFC Converter Using Lossless Snubber With Chaotic Spread Spectrum

open access: yesEnergies, 2023
This paper proposes an improved common mode (CM) electromagnetic interference (EMI) suppression method in switching power supplies. The lossless snubber circuit can reduce du/dt and EMI in the high-frequency band.
Yilong Shi
exaly   +2 more sources
Some of the next articles are maybe not open access.

Related searches:

A New Passive Lossless Snubber

IEEE Transactions on Power Electronics, 2021
Galvanically isolated photovoltaic (PV) microinverters based on single-stage flyback topology have advantages: simplicity, better reliability, and low cost. But isolated flyback topology comes with voltage stresses on semiconductor switches caused by transformer leakage inductance.
Erlan Dzhunusbekov, Sagi Orazbayev
openaire   +1 more source

A Boost PFC Rectifier With a Passive Lossless Snubber Circuit Using Coupled Inductors Methods

open access: yes, 2012
In this paper, a boost PFC rectifier with a novel passive lossless snubber circuit is proposed to minimize switching loss for high power applications. The proposed lossless snubber is composed of the coupled inductors merged to the boost inductor.
Hee-Je Kim, Jee-Hoon Jung, Ju-Won Baek
exaly   +2 more sources

Lossless Snubber Cell for a Soft-Switched Bidirectional Buck–Boost Converter [PDF]

open access: yesIEEE Access, 2020
In this paper, we propose a lossless snubber cell for a soft-switched bidirectional buck-boost converter (BBC). The proposed snubber cell provides all switches with soft-switching conditions in both the bidirectional power flows of the BBC. In addition, the cell also achieves a relatively low circulating current for the snubber operation over a wide ...
Hyung Ik Joo, Sang-Kyoo Han
exaly   +2 more sources

A novel lossless snubber circuit

Proceedings, Fourth Annual IEEE Applied Power Electronics Conference and Exposition, 2003
A simple lossless snubber circuit for use with a switch mode power converter is presented. The circuit uses a capacitor connected between the primary and tertiary windings of a transformer in such a way as to relieve the stress from the power semiconductor switch at both turn-on and turn-off.
L.D. Varga, N.A. Losic
openaire   +1 more source

Flyback lossless passive snubber

2015 IEEE Energy Conversion Congress and Exposition (ECCE), 2015
To increase power conversion density, it is inevitably necessary to increase switching frequency. However, doing so has detrimental effects, including reduced efficiency and increased EMI under hard-switching operation. To prevent the side effects of high switching frequencies, soft switching methods present advantages.
Mehdi Mohammadi, Martin Ordonez
openaire   +1 more source

Home - About - Disclaimer - Privacy