Results 11 to 20 of about 37,444 (305)

Low Voltage Ride-through in DFIG Wind Generators by Controlling the Rotor Current without Crowbars [PDF]

open access: yesEnergies, 2014
Among all the different types of electric wind generators, those that are based on doubly fed induction generators, or DFIG technology, are the most vulnerable to grid faults such as voltage sags.
Jaime Rodríguez Arribas   +3 more
doaj   +4 more sources

Effect of doubly fed induction generatortidal current turbines on stability of a distribution grid under unbalanced voltage conditions [PDF]

open access: yes, 2017
This paper analyses the effects of doubly fed induction generator (DFIG) tidal current turbines on a distribution grid under unbalanced voltage conditions of the grid.
Huang, Bin   +5 more
core   +5 more sources

Fast Coordinated Control of DFIG Wind Turbine Generators for Low and High Voltage Ride-Through [PDF]

open access: yes, 2014
This paper presents a fast coordinated control scheme of the rotor side converter (RSC), the Direct Current (DC) chopper and the grid side converter (GSC) of doubly fed induction generator (DFIG) wind turbine generators (WTGs) to improve the low voltage ...
Ackermann   +7 more
core   +2 more sources

Research on Voltage Stability of Grid-Connected Photovoltaic System Based on Double-Side Voltage Feedback Control

open access: yesZhongguo dianli, 2022
In terms of the problem that the grid-connected photovoltaic DC system is unstable during low voltage ride through (LVRT), an improved double-side voltage control strategy is proposed.
Fei XUE   +3 more
doaj   +1 more source

Low Voltage Ride-Through of Two-Stage Grid-Connected Photovoltaic Systems Through the Inherent Linear Power-Voltage Characteristic [PDF]

open access: yes, 2017
In this paper, a cost-effective control scheme for two-stage grid-connected PhotoVoltaic (PV) systems in Low Voltage Ride-Through (LVRT) operation is proposed. In the case of LVRT, the active power injection by PV panels should be limited to prevent from
Blaabjerg, Frede   +3 more
core   +2 more sources

Probabilistic Short-Circuit Current in Active Distribution Networks Considering Low Voltage Ride-Through of Photovoltaic Generation

open access: yesIEEE Access, 2019
The probabilistic short-circuit current (PSCC) of photovoltaic generation is determined by the voltage sag at the grid connection and the low voltage ride-through of the unit during the grid fault, while the voltage sag and the low voltage ride-through ...
Weiyan Qian   +5 more
doaj   +1 more source

Power Quality Improvement and Low Voltage Ride through Capability in Hybrid Wind-PV Farms Grid-Connected Using Dynamic Voltage Restorer [PDF]

open access: yes, 2018
© 2018 IEEE. Translations and content mining are permitted for academic research only. Personal use is also permitted, but republication/redistribution requires IEEE permission.This paper proposes the application of a dynamic voltage restorer (DVR) to ...
Allaoui, Tayeb   +3 more
core   +2 more sources

On the Conflict between LVRT and Line Protection in LV Distribution Systems with PVs: A Current-Limitation-Based Solution

open access: yesEnergies, 2019
The upcoming adoption of low-voltage-ride-through requirements in low-voltage distribution systems is expected to raise significant challenges in the operation of grid-tied inverters.
Aristotelis Tsimtsios   +4 more
doaj   +1 more source

Low Voltage Ride Through einer synchrongeneratorbasierten Windkraftanlage

open access: yes, 2022
Due to the increased power penetration level of wind energy, wind turbines are now system-relevant components of the power supply. To ensure grid stability, especially during a symmetrical or asymmetrical voltage dip, wind turbines must provide low voltage ride through (LVRT) capability with simultaneous dynamic voltage support ability by feeding ...
openaire   +2 more sources

Comparison of current-limiting strategies during fault ride-through of inverters to prevent latch-up and wind-up [PDF]

open access: yes, 2013
Transient stability of a power network requires that generators remain synchronized and return to normal power export once a fault is cleared. For inverter-interfaced generators, one must ensure that current and voltage limiters do not latch-up and that ...
Bottrell, N, Green, TC
core   +1 more source

Home - About - Disclaimer - Privacy