Mode switching DFIG for low voltage ride through
8th International Conference on Power Electronics - ECCE Asia, 2011With the rapid development of world-wide wind energy generation using doubly fed induction generations (DFIGs), low voltage ride through (LVRT) has become a great concern. This paper focuses on a unique topology of DFIG called IG connection mode to help the DFIG ride through grid faults smoothly.
Wei, Feng, Vilathgamuwa, Don
openaire +2 more sources
Low Voltage Ride Through Characteristics of Grid Forming inverters
2020 21st International Scientific Conference on Electric Power Engineering (EPE), 2020With the certainty of the high share of power electronics in power grid, algorithms for various grid forming inverters have emerged in academia. Due to the grid synchronization strategy of the grid forming inverter is completely different from the current grid following inverters, its dynamic characteristics during grid faults are also different.
Ziqian Zhang +4 more
openaire +1 more source
Comparison of some low voltage ride-through strategies
IECON 2017 - 43rd Annual Conference of the IEEE Industrial Electronics Society, 2017PV system integration with power grid has many challenges. One of these challenges, the disconnection of PV inverters from the grid under grid faults; these disconnections lead to a stability problem in larger scale of PV power plant. This paper is focused on the comparison of some Low voltage ride-through strategies.
Elshiekh K. Mohammedsaeed, Ke Jia
openaire +1 more source
Low-Voltage-Ride-Through-Assistenzsystem für dezentrale Erzeugungseinheiten
e & i Elektrotechnik und Informationstechnik, 2014Wahrend eines Kurzschlusses im Netz nahe einem Synchrongenerator kommt es aufgrund einer verminderten Leistungsabgabe wahrend des Fehlers zu einer Beschleunigung des Rotors. Dies kann zu unerwunscht hohen Polradpendelungen bis hin zum Verlust des Synchronismus des Generators fuhren.
Norbert Essl, Herwig Renner
openaire +1 more source
Low voltage ride through(LVRT) research of DFIG
2013 25th Chinese Control and Decision Conference (CCDC), 2013Nowadays Doubly Fed Induction Generator (DFIG) is used in variable speed wind power plants extensively. Doubly fed induction generator (DFIG) has many advantages such as low cost, reduced losses with an improved efficiency, variable speed operation and improved active and reactive power control capabilities.
Li Lianbing, Zhang Peng
openaire +1 more source
Low-voltage ride-through simulation for microgrid systems
2017 IEEE International Conference on Electro Information Technology (EIT), 2017In contrast to the previous generation of power grid codes, recent standards require that distributed energy resources (DERs) provide low-voltage ride-through (LVRT) capabilities during grid faults. Consequently, the high penetration of DERs in today's power system requires an efficient method of controlling the active and reactive power of those ...
Elham Foruzan +2 more
openaire +1 more source
Low Voltage Ride-Through Response Under High PV Penetration
2019 International Conference on Electrical, Communication, and Computer Engineering (ICECCE), 2019The time variation (weather), photovoltaic (PV) capacity and its location are crucial factors impacting renewable energy sources integration to the Distribution Network. In addition to the above-mentioned constraints, researchers have paid attention on some recently investigated issues caused by PV penetration including; reverse flow of power, voltage ...
Yeboh Ngalo Lucky de Marco +3 more
openaire +1 more source
Low Voltage Ride Through of Wind Energy Systems
2017This chapter titled, “Low Voltage Ride Through of Wind Energy Systems” focuses on the importance of low voltage ride through (LVRT) of wind turbines. The investigation of some selected grid codes has revealed that LVRT has different requirements in different grid codes.
Mehrdad, Tarafdar H, Muttaqi, Kashem M
openaire +2 more sources
Remote detecting low voltage ride through ability of DFIG
TENCON 2015 - 2015 IEEE Region 10 Conference, 2015There are difficulties in detecting low voltage ride through (LVRT) ability of offshore doubly fed induction generator (DFIG) because of complexity of sea condition. In this paper, a new scheme is put forward to solve this problem. This new scheme takes into account the effect of submarine cables on transient process of circuit, and the influence on ...
Caike Xie +2 more
openaire +1 more source
Testing Low Voltage Ride Through capabilities of solar inverters
Electric Power Systems Research, 2013Abstract The increase in the rated power of PV inverters has brought with it new requirements, such as Low Voltage Ride Through and reactive power compensation. Field tests in PV plants are too expensive in terms of production losses, and therefore laboratory tests have become a simple, flexible and inexpensive alternative.
J. Eloy-Garcia Carrasco +5 more
openaire +1 more source