Results 91 to 100 of about 20,128 (303)

Axin2 as regulatory and therapeutic target in newborn brain injury and remyelination. [PDF]

open access: yes, 2011
Permanent damage to white matter tracts, comprising axons and myelinating oligodendrocytes, is an important component of brain injuries of the newborn that cause cerebral palsy and cognitive disabilities, as well as multiple sclerosis in adults. However,
Baranzini, Sergio E   +11 more
core   +3 more sources

Generating Dynamic Structures Through Physics‐Based Sampling of Predicted Inter‐Residue Geometries

open access: yesAdvanced Science, EarlyView.
While static structure prediction has been revolutionized, modeling protein dynamics remains elusive. trRosettaX2‐Dynamics is presented to address this challenge. This framework leverages a Transformer‐based network to predict inter‐residue geometric constraints, guiding conformation generation via physics‐based iterative sampling. The resulting method
Chenxiao Xiang   +3 more
wiley   +1 more source

A sub-1 V, 26 μw, low-output-impedance CMOS bandgap reference with a low dropout or source follower mode [PDF]

open access: yes, 2011
We present a low-power bandgap reference (BGR), functional from sub-1 V to 5 V supply voltage with either a low dropout (LDO) regulator or source follower (SF) output stage, denoted as the LDO or SF mode, in a 0.5-μm standard digital CMOS process with V ...
Kwong, DKK, Ng, DCW, Wong, N
core   +1 more source

Real‐Time and High‐Resolution NIR‐II‐L Imaging of Netrin‐1‐Mediated Neurovascular Coupling Driven by Dose‐Dependent Electroacupuncture

open access: yesAdvanced Science, EarlyView.
Disrupted neurovascular coupling contributes to ovarian dysfunction in polycystic ovary syndrome. Using near‑infrared II long‑wavelength imaging, this study visualizes how electroacupuncture dynamically regulates ovarian blood vessels in vivo. Immediate and cumulative stimulation elicit distinct vascular responses via a Netrin‐1 dependent mechanism ...
Yicong Wang   +15 more
wiley   +1 more source

Integrated Ultrasound Device for Precision Bladder Volume Monitoring via Acoustic Focusing and Machine Learning

open access: yesAdvanced Science, EarlyView.
We present a conformable wearable ultrasound patch for noninvasive bladder volume monitoring. A flexible PZT array combined with a concave acoustic lens concentrates acoustic energy and improves depth selectivity through the anterior pelvic wall.
Long Long Cao   +4 more
wiley   +1 more source

A Low-Power, Fast Transient Response Low-Dropout Regulator Featuring Bi-Directional Level Shifting for Sensor Applications

open access: yesEngineering Proceedings
Wireless sensor network (WSN) is an important component of healthcare. The design of the power management unit for WSN poses significant challenges, as it not only needs to achieve good current efficiency but also requires high power supply rejection ...
Hao Huang, Jie Cui
doaj   +1 more source

Design and calibration method for precise temperature sensor [PDF]

open access: yesInternational Journal of Electronics and Telecommunications
This paper presents the design of the temperature sensor and analysis of different calibration methods. The main aspect of the analysis was optimization of the number and location of the measurement points needed to perform the calibration for a given ...
Kamil Stepniewski   +4 more
doaj   +1 more source

Urea‐Formaldehyde Resin Confined Silicon Nanodots Composites: High‐Performance and Ultralong Persistent Luminescence for Dynamic AI Information Encryption

open access: yesAdvanced Science, EarlyView.
Schematic illustration of SiNDs composite materials synthesis and its internal photophysical process mechanism. And an AI‐assisted dynamic information encryption process. ABSTRACT Persistent luminescence materials typically encounter an intrinsic trade‐off between high phosphorescence quantum yield (PhQY) and ultralong phosphorescence lifetime.
Yulu Liu   +9 more
wiley   +1 more source

Design of a high current LDO based on load tracking technology

open access: yesDianzi Jishu Yingyong
This paper presents an effective load tracking compensation scheme to improve the loop stability of high current low-dropout linear regulator (LDO). By the proposed technique, the influence of variable load on the loop stability is eliminated, besides ...
Zhu Qi, Huang Denghua
doaj   +1 more source

Characterization of the FE-I4B pixel readout chip production run for the ATLAS Insertable B-layer upgrade

open access: yes, 2012
The Insertable B-layer (IBL) is a fourth pixel layer that will be added inside the existing ATLAS pixel detector during the long LHC shutdown of 2013 and 2014.
Backhaus, Malte
core   +1 more source

Home - About - Disclaimer - Privacy