Results 111 to 120 of about 11,832,040 (287)

Review Paper: A Review on Brain Stimulation Using Low Intensity Focused Ultrasound

open access: yesBasic and Clinical Neuroscience, 2016
Brain stimulation techniques are important in both basic and clinical studies. Majority of well-known brain stimulating techniques have low spatial resolution or entail invasive processes.
Ehsan Rezayat, Iman Ghodrati Toostani
doaj  

Deciphering the Photopolymerization‐Induced Nanostructures and Interface Formation for Submicrometer Additive Manufacturing

open access: yesAdvanced Functional Materials, EarlyView.
This work reveals the UV‐curing‐induced monomer‐rich domain, oligomer‐rich domain, and entangled oligomer domain. The cured submicron films in stressed state induce interlayer nano‐wrinkle structures during the deposition of the second layer. Stress‐free cured films in relaxed state form non‐diffusive, diffusive and semi‐diffusive interlayer ...
Shouzheng Chen   +13 more
wiley   +1 more source

Sacrificial‐Layer‐Assisted Heat‐Affected‐Zone Suppression in Laser Patterning of PET for High‐Performance Flexible Devices

open access: yesAdvanced Functional Materials, EarlyView.
A removable sacrificial polymer layer engineers the thermal boundary condition during nanosecond laser ablation of PET, suppressing heat‐affected‐zone formation without relying on costly ultrafast lasers. This strategy enables deep, high‐aspect‐ratio trenches with no detectable heat‐affected zone, templating silver‐filled mesh electrodes with record ...
Mehdi Zarei   +3 more
wiley   +1 more source

HIGH-INTENSITY FOCUSED ULTRASOUND TREATMENT OF LATE-STAGE PANCREATIC BODY CARCINOMA: OPTIMAL TUMOR DEPTH FOR SAFE ABLATION

open access: yes, 2014
Objective criteria are currently not available for assessing the extent of ablation by high-intensity focused ultrasound (HIFU). A retrospective review was conducted in Chinese patients with late-stage pancreatic body carcinoma treated with 1 h/d ...
Miao, Li-Ying   +8 more
core   +1 more source

Reclassifying transcranial pulse stimulation as TNUS: Nonlinear mechanics necessitate departure from the ITRUSST framework

open access: yesBrain Stimulation
Background: Transcranial ultrasound has emerged as a promising non-invasive neuromodulation modality for Alzheimer's disease (AD). However, its clinical translation is hindered by inconsistent biophysical classification between quasi-linear low-intensity
Qinxi Luo   +11 more
doaj   +1 more source

Nitride MXenes Beyond Carbides: Bridging the Gap Between Computational Prediction and Experimental Realization

open access: yesAdvanced Functional Materials, EarlyView.
Nitride MXenes remain constrained by a persistent gap between computational prediction and experimental realization. This Review identifies the thermodynamic, kinetic, and chemical barriers limiting their synthesis, critically evaluates emerging fabrication routes, and proposes a multidimensional computational‐experimental framework to accelerate the ...
Naresh Varnakavi, Masoud Soroush
wiley   +1 more source

Effects of high-intensity focused ultrasound on the intervertebral disc: A potential therapy for disc herniations

open access: yes, 2006
Purpose. To determine the potential application of high-intensity focused ultrasound for the minimally invasive treatment of herniated intervertebral discs by developing a probe that produces sufficiently high temperature locally to shrink collagen ...
Lars Lidgren   +15 more
core   +1 more source

Structure‐Property Relationships in Catecholamine Coatings for Broad Surface Functionalization

open access: yesAdvanced Functional Materials, EarlyView.
Inspired by mussel adhesive proteins (MAPs), six catecholamine molecules with different molecular structure were systematically characterized and compared based on their ability to form homogeneous, reactive coatings. Highlighting candidates capable of balancing coating properties of interest, their successful use as primer layers for organic and ...
Caroline F. Harms   +5 more
wiley   +1 more source

Low intensity focused ultrasound stimulation in stroke: A phase I safety & feasibility trial

open access: yesBrain Stimulation
Objective: We aimed to determine the maximum safe spatial-peak pulse-average intensity (ISPPA) of low-intensity focused ultrasound stimulation (LIFUS) in stroke patients and explore its effect on motor learning and corticospinal excitability. Methods: We
Ziping Huang   +10 more
doaj   +1 more source

Unique Role of Microstructure of a Bioimplant Zinc Alloy and Protein Content of Simulated Body Fluid in Corrosion and Fracture

open access: yesAdvanced Functional Materials, EarlyView.
BSA addition to physiological solutions enhances resistance of a Zn alloy to stress corrosion cracking (SCC) but reduces its corrosion resistance. Extended surface characterization explains the contrasting influences on corrosion and SCC. Unexpectedly, the alloy suffers transgranular SCC (TGSCC), despite extensive grain boundary precipitation. Thorough
RK Singh Raman   +9 more
wiley   +1 more source

Home - About - Disclaimer - Privacy