Results 281 to 290 of about 13,607,711 (325)
Some of the next articles are maybe not open access.
Identifying Topology of Low Voltage Distribution Networks Based on Smart Meter Data
IEEE Transactions on Smart Grid, 2018In a power distribution network, the network topology information is essential for an efficient operation. This network connectivity information is often not available at the low voltage (LV) level due to uninformed changes that happen from time to time.
Satya Jayadev Pappu +3 more
semanticscholar +1 more source
High Voltage Versus Low Voltage
Physical Therapy, 1986To the Editor: The conclusions stated in the article “High Voltage Versus Low Voltage Electrical Stimulation: Force of Induced Muscle Contraction and Perceived Discomfort in Healthy Subjects” (Physical Therapy 66:1209–1214, 1986) contradict an extensive body of literature1–5 that suggests that optimal pulse duration for neuromuscular stimulation in ...
openaire +1 more source
Low-Voltage Low-Power Amplifiers
1995Low-voltage and low-power amplifiers are strongly limited in dynamic range (DR) and bandwidth (B). The maximum dynamic-range/supply-power ratio is restricted to DR/sub max//P/sub sup/ = /spl pi//16 kTBe by thermal noise in resistors. To obtain this maximum value, several rail-to-rail (R-R) input stages and R-R output stages biased in class-AB are ...
Ron Hogervorst +3 more
openaire +1 more source
Enabling ultra-low-voltage switching in BaTiO3
Nature Materials, 2022Yizhe Jiang +15 more
semanticscholar +1 more source
2020
This chapter examines DML performance, energy consumption, static noise margins, delay distribution, robustness, and other design metrics under low-voltage operation. It still focuses on the gate level and DML operations in subthreshold and near-threshold regions illustrated using the transregional model.
Itamar Levi, Alexander Fish
openaire +1 more source
This chapter examines DML performance, energy consumption, static noise margins, delay distribution, robustness, and other design metrics under low-voltage operation. It still focuses on the gate level and DML operations in subthreshold and near-threshold regions illustrated using the transregional model.
Itamar Levi, Alexander Fish
openaire +1 more source
IEEE transactions on power electronics, 2018
In a dc pulsed power supply (PPS), its instantaneous output power is pulsed, and its input power is required to be constant. In order to balance the instantaneous power difference, a storage capacitor is usually connected to the output terminal of the ...
Xinze Huang +4 more
semanticscholar +1 more source
In a dc pulsed power supply (PPS), its instantaneous output power is pulsed, and its input power is required to be constant. In order to balance the instantaneous power difference, a storage capacitor is usually connected to the output terminal of the ...
Xinze Huang +4 more
semanticscholar +1 more source
Low-voltage Low-power Amplifiers
1993 IEEE International Symposium on Circuits and Systems, 2002J.H. Huijsing +2 more
openaire +1 more source
1988
The measurement of power must rely on a reference that is derived from the standards of voltage and resistance. Various techniques have been developed for combining these two standards in such a way as to provide a practical and convenient power standard. The power bridge, based on the current comparator, is one way of achieving this objective.
openaire +1 more source
The measurement of power must rely on a reference that is derived from the standards of voltage and resistance. Various techniques have been developed for combining these two standards in such a way as to provide a practical and convenient power standard. The power bridge, based on the current comparator, is one way of achieving this objective.
openaire +1 more source
Low-solvation electrolytes for high-voltage sodium-ion batteries
Nature Energy, 2022Yan Jin +15 more
semanticscholar +1 more source

