Results 1 to 10 of about 7,394 (245)

Research on the influence of load model with distributed PV generation on the voltage stability of receiving-end power grid

open access: yesEnergy Reports, 2023
The low voltage ride-through (LVRT) characteristics of DPV are first analyzed in this paper, and then the influence of the LVRT control strategies and parameters of PDGs on the grid voltage stability is studied.
Qi Wang   +6 more
doaj   +1 more source

Implementation Strategy of Test Facility Based on Auto-Transformer for LVRT/HVRT Evaluation of Large-Scale Wind Turbine

open access: yesEnergies, 2023
In accordance with South Korea’s recent 2030 Carbon Neutral Plan, an 8GW offshore wind farm is planned for construction in the South-west Sea. Therefore, it is expected that large-scale wind turbines will be installed, and these turbines must operate ...
Byungki Kim   +3 more
doaj   +1 more source

Research on HIL-based HVRT and LVRT automated test system for photovoltaic inverters

open access: yesEnergy Reports, 2021
As an important capability of the photovoltaic grid-connected inverter, high voltage ride-through (HVRT) and low voltage ride-through (LVRT) capability are related to the stability of the whole power grid system.
Fei Li   +3 more
doaj   +1 more source

Adjustable unbalanced current controller for tranformerless PV generation to suppress DC voltage ripples of inverter in low‐voltage ride‐through (LVRT) operation [PDF]

open access: yesIET Renewable Power Generation, 2022
Abstract Low voltage ride‐trough (LVRT) feature is compulsory for each grid‐connected inverter to support the grid by injecting reactive power in low voltage conditions. It is well known that the operation of an inverter in a normal grid condition is different from its operation in a faulty one.
Kadri, Afshin   +3 more
openaire   +4 more sources

LVRT Control Strategy for Asymmetric Faults of DFIG Based on Improved MPCC Method

open access: yesIEEE Access, 2021
In the case of asymmetric fault, the modern new power grid requires that the doubly-fed induction generator (DFIG) still has good low voltage ride-through (LVRT) capabilities. To solve this problem, a low voltage ride-through control strategy based on an
Can Ding, Yunwen Chen, Taiping Nie
doaj   +1 more source

Development of HVRT and LVRT Control Strategy for PMSG-Based Wind Turbine Generators

open access: yesEnergies, 2020
Various challenges are acknowledged in practical cases with high wind power penetration. Fault ride-through (FRT) capability has become the most dominant grid integration requirements for the wind energy conversion system worldwide. The high voltage ride-
Liang Yuan   +5 more
doaj   +1 more source

A Comprehensive Review of Control Strategies to Overcome Challenges During LVRT in PV Systems

open access: yesIEEE Access, 2021
Due to the high penetration of grid-connected photovoltaic (GCPV) systems, the network operators are regularly updating the grid codes to ensure that the operation of GCPV systems will assist in maintaining grid stability.
Jyoti Joshi   +3 more
doaj   +1 more source

Fluctuation Suppression of DC-Link Voltage Using Control of Converters Connected with DC Distributed Generation

open access: yesEnergies, 2020
Due to the increase in DC load and DC Power generation, the need for DC power system is emerging. Accordingly, FRT (fault ride through) and LVRT (low voltage ride through), which are related regulations for renewable energy sources, have been enacted ...
Sang-Jae Choi, Sung-Hun Lim
doaj   +1 more source

A General Mathematical Model for LVRT Capability Assessment of DER-Penetrated Distribution Networks

open access: yesIEEE Access, 2020
Low voltage ride through (LVRT) is one of the indispensable issues of recent decade in the context of grid codes. LVRT stands for the ability of a generation facility to stay connected during the voltage dip.
Pouya Salyani   +4 more
doaj   +1 more source

Multi-Functional PV Inverter With Low Voltage Ride-Through and Constant Power Output

open access: yesIEEE Access, 2022
Renewable photovoltaic (PV) energy is a primary contributor to sustainable power generation in microgrids. However, PV grid-tied generators remain functional as long as the grid voltage and the input PV source remain normal.
Muhammad Talha   +5 more
doaj   +1 more source

Home - About - Disclaimer - Privacy