Results 291 to 300 of about 903,606 (393)
A Magnetically Controlled Capsule Robot with Biopsy Capability for Intestinal Applications. [PDF]
Zheng L +8 more
europepmc +1 more source
By fabricating and covalently assembling gelatin methacryloyl (GelMA) porous microgels, a new class of granular hydrogel scaffolds with hierarchical porosity is developed. These scaffolds have a significantly higher void fraction than their counterparts made up of nonporous microgels, enhancing cell recruitment and tissue integration. This research may
Alexander Kedzierski +9 more
wiley +1 more source
Automatic position monitoring of endotracheal breathing tubes using a magnetic sensor array. [PDF]
Riemschneider T +4 more
europepmc +1 more source
Wearable Haptic Feedback Interfaces for Augmenting Human Touch
The wearable haptic feedback interfaces enhance user experience in gaming, social media, biomedical instrumentation, and robotics by generating tactile sensations. This review discusses and categorizes current haptic feedback interfaces into force, thermal, and electrotactile stimulation‐based haptic feedback interfaces, elucidating their current ...
Shubham Patel +3 more
wiley +1 more source
Real-time electron spectrometer utilizing a permanent magnet and diode detector array. [PDF]
Heath MW +3 more
europepmc +1 more source
A biofabricated 3D in vitro model recapitulating endochondral ossification (ECO) is described, mimicking the steps from condensation to chondrogenesis and hypertrophy, culminating with vascularization of the hypertrophic construct. As a model proof of concept application, Ewing Sarcoma cells are seeded in the model, showing modifications in their ...
Maria Vittoria Colombo +13 more
wiley +1 more source
Magnetic Confinement of a Bubble of Supercooled <sup>3</sup>He-A. [PDF]
Whitehead L +11 more
europepmc +1 more source
The separation of Helium gas from natural gas is challenging but highly important. MIL‐116(Ga), a “non‐porous” metal–organic framework is used as a molecular sieve to separate He from CH4. Druse‐like MIL‐116(Ga) particles are integrated into polysulfone mixed matrix membranes.
Ayisha Komal +10 more
wiley +1 more source
Numerical Investigation of Halbach-Array-Based Flexible Magnetic Sensors for Wide-Range Deformation Detection. [PDF]
Han Y +5 more
europepmc +1 more source
This study examines how manufacturing uncertainties in Curie temperatures (1.5–2°C) affect multilayer active magnetic regenerators (AMR). While increasing the number of magnetocaloric layers boosts cooling power, performance degrades due to temperature variations.
Urban Tomc +6 more
wiley +1 more source

