Results 221 to 230 of about 49,303 (301)

Towards Clinical Translation of Intravoxel Incoherent Motion MRI: Acquisition and Analysis Consensus Recommendations

open access: yesJournal of Magnetic Resonance Imaging, Volume 63, Issue 6, Page 1782-1801, June 2026.
ABSTRACT Intravoxel incoherent motion (IVIM) MRI allows for simultaneous assessment of tissue microcirculation (perfusion) and diffusion of water. In single‐center studies, IVIM has shown great potential for diagnosis, treatment outcome prediction, and treatment monitoring for many different diseases and organs.
Eric E. Sigmund   +23 more
wiley   +1 more source

MRI for Lung Cancer Management: Any Closer to Clinical Application?

open access: yesJournal of Magnetic Resonance Imaging, Volume 63, Issue 6, Page 1546-1561, June 2026.
ABSTRACT Management of lung cancer (LC) encompasses screening, diagnosis, staging, radiotherapy planning and guidance, therapy monitoring and surveillance. Across these domains, magnetic resonance imaging (MRI) offers a range of morphological and functional imaging capabilities—including diffusion‐weighted imaging (DWI), dynamic contrast‐enhanced (DCE)
Juergen Biederer   +10 more
wiley   +1 more source

Impact of Partial Echo on 4D Flow MRI: The Insight From Synthetic MRI

open access: yesMagnetic Resonance in Medicine, Volume 95, Issue 6, Page 3462-3475, June 2026.
ABSTRACT Purpose The aim of this study is to investigate the impact of the partial echo on 4D flow MRI sequences thanks to in silico coupled MRI‐CFD (computational fluid dynamics) simulations. Methods Two sequences are studied: one with a full echo (FE) and another using partial echo (PE) with an echo symmetry fraction of 0.75.
Morgane Garreau   +6 more
wiley   +1 more source

Toward Super‐Resolution Reconstruction of Diffusion–Relaxation MRI Using Slice Excitation With Random Overlap (SERO)

open access: yesMagnetic Resonance in Medicine, Volume 95, Issue 6, Page 3213-3226, June 2026.
ABSTRACT Purpose Diffusion MRI probes tissue microstructure, but low SNR and limited resolution hinder detection of features and parameter estimates. We introduce slice excitation with random overlap (SERO), which enables variable repetition times (TRs) and diffusion weighting within a single shot.
Felix Mortensen   +7 more
wiley   +1 more source

Respiratory Motion‐Corrected Model‐Based 3D Water‐Fat MRA of the Thorax at 0.55 T

open access: yesMagnetic Resonance in Medicine, Volume 95, Issue 6, Page 3241-3252, June 2026.
ABSTRACT Purpose The goal of this study was to develop a 5‐min 3D MRA acquisition at 0.55 T with predictable scan time, 100% data efficiency, and robust water‐fat separation. Methods For full data efficiency, the proposed method combined self‐gating with retrospective motion correction while ensuring a predictable 5‐min scan time.
Robert Stoll   +5 more
wiley   +1 more source

Flexible eddy current array measurement system for crack detection in weld zones of steel structures. [PDF]

open access: yesCommun Eng
Trung LQ   +6 more
europepmc   +1 more source

Spectral Representation of Neurochemicals With Phase, Frequency Offset, and Lineshape Invariance: Application to JPRESS for In Vivo Concentration and T2 Mapping by Deep Learning

open access: yesMagnetic Resonance in Medicine, Volume 95, Issue 6, Page 3052-3064, June 2026.
ABSTRACT Purpose Using artificial intelligence neural networks to generate a representation that maps the input directly to neurochemical concentrations and metabolite‐level average transverse relaxation times (T2). Methods The proposed model used time‐domain JPRESS data as input and was trained to be invariant to phase shifts, frequency offsets, and ...
Yan Zhang, Jun Shen
wiley   +1 more source

Home - About - Disclaimer - Privacy