Results 101 to 110 of about 372,562 (311)
The spatial sensitivity of an erbium doped optical fibre distributed feedback (DFB) laser to an external magnetic field is reported. Intrinsic birefringence of the laser cavity allows lasing in two orthogonal modes.
Yuan Yao +3 more
core +1 more source
FREQUENCY OF FORMATION OF VAPOR BUBBLES IN A TWO-LAYER MEDIUM MAGNETIC-NONMAGNETIC LIQUID
Introduction: a method for measuring the frequency of the formation of vapor bubbles in the boiling of opaque fluids using a two-layer system is proposed and implemented: an opaque - transparent medium.
Alexander Aleksandrovich Yanovsky +1 more
doaj
Demagnetizing Factor of Magnetic Fluid.
The evaluation of demagnetizing factors of water-based magnetic fluids is performed from the comparison between an experiment and calculation and it is concluded that a demagnetizing factor of about 0.1 is recommendable.
MATSUNO, Yoshiyuki +3 more
openaire +2 more sources
Advancing Age Modulates Associations Between Cognitive Impairment and Brain Volumes in Early MS
ABSTRACT Introduction Cognitive impairment is common in multiple sclerosis (MS), but manifestations following the first demyelinating event are relatively unexplored. We investigated cross‐sectional associations between magnetic resonance imaging (MRI)–derived brain volumes and the presence of cognitive impairment outcomes five years after the first ...
Piriyankan Ananthavarathan +14 more
wiley +1 more source
ABSTRACT Background Central nervous system (CNS) inflammatory demyelinating syndromes, including multiple sclerosis (MS), aquaporin‐4 antibody–positive neuromyelitis optica spectrum disorder (AQP4 + NMOSD), and myelin oligodendrocyte glycoprotein (MOG) antibody–associated disease (MOGAD), occasionally overlap.
Bade Gulec +6 more
wiley +1 more source
Thermo-magnetic convection of paramagnetic fluids with non-instantaneous heating
The unsteady boundary-layer development for thermomagnetic\ud convection of paramagnetic fluids inside a square cavity has been considered in this study.
Saha, Suvash C., Gu, YuanTong
core
Experimental Study on Thermal Conductivity of Water-Based Magnetic Fluid Loaded with Different Nanoparticles. [PDF]
Su Z +5 more
europepmc +1 more source
ABSTRACT Background and Purpose White matter hyperintensities (WMH) are a core neuroimaging marker of cerebral small vessel disease (CSVD). Sleep apnoea (SA) is a recognized vascular risk factor, but its associations with regional WMH burden, short‐interval WMH change and cognitive performance in population‐based cohorts remain incompletely defined. We
Peng Cheng +4 more
wiley +1 more source
Interaction of magnetic beads in microfluidic systems : fundamentals and applications
Wittbracht F. Interaction of magnetic beads in microfluidic systems : fundamentals and applications.
Wittbracht, Frank
core
Noncontact gravity compensator with magnetic fluid seals
In vertical positioning systems, the friction force and the gravity load cause significant error. In order to minimize the effect of friction and gravity load, this paper presents the noncontact gravity compensator applying magnetic fluid seals.
Noriyuki HASEGAWA +2 more
doaj +1 more source

