Review of Failure Mechanisms of Steel Wire Ropes Under Heavy-Load Conditions and the Anti-Friction Effects of Gel-like Grease. [PDF]
Peng H +6 more
europepmc +1 more source
Quantitative Evaluation of Mechanical Properties of Hydrogen Transmission Pipelines Based on Weak Magnetic Detection. [PDF]
Wang S, Sun X, Miao X, Ye H.
europepmc +1 more source
Exploring Weak Magnetic Signal Characteristics of Pipeline Welds: Insights into Stress Non-Uniformity Effects. [PDF]
Fan X, Yang L.
europepmc +1 more source
Related searches:
Analysis of Magnetic-Flux Leakage (MFL) Data for Pipeline Corrosion Assessment
IEEE Transactions on Magnetics, 2020Oil and gas pipelines transport and distribute large quantities of oil products and natural gas to industrial and residential customers over a long distance. However, pipeline failures could lead to enormous hazards and safety issues. Metal loss, due to corrosion, is a significant cause for pipeline failures.
Uchenna Anyaoha, Xiang Peng
exaly +2 more sources
Study on the Magnetic Flux Leakage (MFL) for Fillet Weld
Advanced Materials Research, 2012The magnetic flux leakage (MFL) technique is widely used as a Non-Destructive Testing (NDT) method for welds [1]. Because of the specialty of fillet weld structure, the defect may not be in the location suitably detected, which is normally at the center of yoke poles, and the rate of detect-ability would decline.
Chun Fei Guo, Li Jun Wang, Min Zhang
exaly +2 more sources
The interaction of multiple magnetic circuits in magnetic flux leakage (MFL) inspection
2014 IEEE Far East Forum on Nondestructive Evaluation/Testing, 2014In this paper, a multi-magnetizer comprise of three units was introduced, of this multi-magnetizer, permanent magnet, poke, brush, and pipeline form a closed magnetic circuit in each unit, and each unite can be adjusted relative angle to meet the requirement for detection of pipes with different size. The investigation focuses on the interaction due to
null Gao Ting-yan +3 more
exaly +2 more sources
Nondestructive testing systems with magnetic flux leakage (MFL)
Paper P100, 1 S.Ferromagnetic components used in mechanical, automotive and civil engineering are mostly subject to high mechanical loads. Cracks, which may form during manufacture or in use, may lead to a complete failure of the component in the worst ...
Youssef, Sargon +3 more
openaire +2 more sources
Iman Ahadi Akhlaghi, Saeed Kahrobaee
exaly +2 more sources
Non-destructive Inspection of Pipeline by Magnetic Flux Leakage (MFL) Method
Proceedings in Technology TransferHong Quang Pham, Minh Hung Vu
exaly +2 more sources
Magnetic flux leakage (MFL) for the non-destructive evaluation of pre-stressed concrete structures
2010H -J Krause
exaly +2 more sources