Results 121 to 130 of about 382,379 (299)

Portable Low‐Field Magnetic Resonance Imaging in People With Human Immunodeficiency Virus

open access: yesAnnals of Clinical and Translational Neurology, EarlyView.
ABSTRACT Objective The aging population of people with HIV (PWH) raises heightened concerns regarding accelerated aging and dementia. Portable, low‐field MRI (LF‐MRI) is an innovative technology that could enhance access and facilitate routine monitoring of PWH.
Annabel Sorby‐Adams   +14 more
wiley   +1 more source

Basilar Artery Occlusion Stroke Managed With Tenecteplase Versus Alteplase Before Endovascular Treatment (BAO‐TNK)

open access: yesAnnals of Clinical and Translational Neurology, EarlyView.
ABSTRACT Objective To compare the effectiveness and safety of tenecteplase (TNK) versus alteplase (TPA) in patients with basilar artery occlusion prior to endovascular treatment (EVT). Methods In this retrospective multicenter study (BAO‐TNK), we analyzed consecutive BAO patients from 14 U.S.
Rahul R. Karamchandani   +38 more
wiley   +1 more source

Dual-Layer Anomalous Hall Effect Sensor for Enhanced Accuracy and Range in Magnetic Field Detection

open access: yesNanomaterials
This study introduces a method aimed at enhancing both the accuracy and the range of magnetic field sensors, which are two critical parameters, in a novel NiCo2O4-based anomalous Hall effect sensor.
Sitong An   +5 more
doaj   +1 more source

A self calibrating, magnetic sensor approach accurately positions an aortic damage control stent in a porcine model. [PDF]

open access: yesTrauma Surg Acute Care Open, 2023
Kenawy DM   +6 more
europepmc   +1 more source

Network Localization of Fatigue in Multiple Sclerosis

open access: yesAnnals of Clinical and Translational Neurology, EarlyView.
ABSTRACT Background Fatigue is among the most common symptoms and one of the main factors determining the quality of life in multiple sclerosis (MS). However, the neurobiological mechanisms underlying fatigue are not fully understood. Here we studied lesion locations and their connections in individuals with MS, aiming to identify brain networks ...
Olli Likitalo   +12 more
wiley   +1 more source

Single element magnetic suspension actuator [PDF]

open access: yes, 1991
The invention, a single element magnetic suspension actuator with bidirectional force capability along a single axis, includes an electromagnet and a nonmagnetic suspended element.
Groom, Nelson J.
core   +1 more source

Frailty Exacerbates Disability in Progressive Multiple Sclerosis

open access: yesAnnals of Clinical and Translational Neurology, EarlyView.
ABSTRACT Background To evaluate frailty in severe progressive multiple sclerosis (PMS) and to investigate the underlying mechanisms. Methods This prospective, cross‐sectional, multicenter study enrolled a late severe PMS group requiring skilled nursing (n = 53) and an age, sex, and disease duration‐matched control PMS group (n = 53).
Taylor R. Wicks   +10 more
wiley   +1 more source

Shaping Perpendicular Magnetic Anisotropy of Co2MnGa Heusler Alloy Using Ion Irradiation for Magnetic Sensor Applications. [PDF]

open access: yesSensors (Basel), 2023
Mahendra A   +7 more
europepmc   +1 more source

Fibrinogen Changes Before and After Intravenous Thrombolysis as Predictors of Cerebral Injury and Clinical Outcomes in Acute Ischemic Stroke: A Multicenter Prospective Cohort Study

open access: yesAnnals of Clinical and Translational Neurology, EarlyView.
ABSTRACT Objective Plasma fibrinogen is essential in thrombosis and fibrinolysis, yet its dynamic changes pre‐ and post‐intravenous thrombolysis (IVT) for predicting brain injury severity and prognosis in acute ischemic stroke (AIS) patients remain unclear.
Wenhai Zhai   +28 more
wiley   +1 more source

Continuous Monitoring of Blood Pressure and Vascular Hemodynamic Properties With Miniature Extravascular Hall-Based Magnetic Sensor. [PDF]

open access: yesJACC Basic Transl Sci, 2023
Magkoutas K   +6 more
europepmc   +1 more source

Home - About - Disclaimer - Privacy