Results 31 to 40 of about 98,037 (215)
This paper reports a novel micro-fluxgate sensor based on a double-layer magnetic core of a Fe–Co–B-based amorphous ribbon. The melt-spinning technique was carried out to obtain a Fe–Co–B-based amorphous ribbon composite of Fe58.1Co24.9B16Si1, and the ...
Lei Guo +5 more
doaj +1 more source
Magnetic Properties of FeNi-Based Thin Film Materials with Different Additives
This paper presents a study of FeNi-based thin film materials deposited with Mo, Al and B using a co-sputtering process. The existence of soft magnetic properties in combination with strong magneto-mechanical coupling makes these materials attractive ...
Cai Liang +5 more
doaj +1 more source
Tensor coaxial calibration of magnetic sensor array
In order to effectively solve the influence of the magnetic sensor array error caused by axial inconsistency on the measurement accuracy, an array composed of four fluxgate sensors is built by using the Euler rotation matrix, and the consistency ...
LEI Yiqin +4 more
doaj +1 more source
ABSTRACT Pediatric gastroenteropancreatic neuroendocrine neoplasms (GEP‐NENs) are extremely rare and clinically heterogeneous. Management has largely been extrapolated from adult practice. This European Standard Clinical Practice Guideline (ESCP), developed by the EXPeRT network in collaboration with adult NEN experts, provides (adult) evidence ...
Michaela Kuhlen +23 more
wiley +1 more source
ABSTRACT Pediatric radiation therapy presents unique challenges compared to adult treatments, including those of immobilization, potential need for sedation, and the critical importance of accurate, reproducible positioning. Additionally, heightened attention to imaging doses is necessary to minimize long‐term toxicity in survivors.
Parham Alaei +17 more
wiley +1 more source
In the complex underwater environment, the performance of microelectro-mechanical system sensors is degraded sharply and the errors will become much larger.
Haoqian Huang +6 more
doaj +1 more source
Study on the Technology of Ultra-high Sensitive Wide-band Magnetic-feedback Inductive Magnetic Sensor [PDF]
It analyses the composition and principle of high-sensitive wide-band magnetic-feedback inductive magnetic sensor to fulfil the demand of high-sensitive wide-band magnetic sensor in geological exploration.
Liu Yong +6 more
doaj +1 more source
ABSTRACT Hemophilic arthropathy remains the leading morbidity in hemophilia despite modern prophylaxis, and early joint damage may be missed by routine exams. This study explored T2* MRI as a noninvasive biomarker of hemosiderin deposition in pediatric hemophilia.
Jessica Garcia +6 more
wiley +1 more source
ABSTRACT Introduction Anthracycline‐related cardiac remodeling precedes heart failure in childhood cancer survivors. The objectives of this study were to determine the relationships between patient‐specific factors, moderate‐to‐vigorous physical activity (MVPA), and cardiac remodeling.
Hari K. Narayan +15 more
wiley +1 more source
On the Origin of Signal and Bandwidth of Converse Magnetoelectric Magnetic Field Sensors
Converse magnetoelectric sensors enable the detection of low‐frequency and low‐amplitude magnetic fields over a bandwidth of several kilohertz by combining the electrical excitation of a magnetoelectric resonator via a piezoelectric layer with an ...
Elizaveta Spetzler +9 more
doaj +1 more source

