LOW-FREQUENCY MAGNETIC FIELD SHIELDING BY A CIRCULAR PASSIVE LOOP AND CLOSED SHELLS

open access: yesElectrical engineering & Electromechanics, 2016
Purpose. To analyze the shielding factors for a circular passive loop and conductive closed shells placed in a homogeneous low-frequency magnetic field. Methodology. We have obtained simplified expressions for the shielding factors for a circular passive
V.S. Grinchenko   +2 more
doaj   +1 more source

Enzymatic degradation of biopolymers in amorphous and molten states: mechanisms and applications

open access: yesFEBS Open Bio, EarlyView.
This review explains how polymer morphology and thermal state shape enzymatic degradation pathways, comparing amorphous and molten biopolymer structures. By integrating structure–reactivity principles with insights from thermodynamics and enzyme engineering, it highlights mechanisms that enable efficient polymer breakdown.
Anđela Pustak, Aleksandra Maršavelski
wiley   +1 more source

Portable Low‐Field Magnetic Resonance Imaging in People With Human Immunodeficiency Virus

open access: yesAnnals of Clinical and Translational Neurology, EarlyView.
ABSTRACT Objective The aging population of people with HIV (PWH) raises heightened concerns regarding accelerated aging and dementia. Portable, low‐field MRI (LF‐MRI) is an innovative technology that could enhance access and facilitate routine monitoring of PWH.
Annabel Sorby‐Adams   +14 more
wiley   +1 more source

Magnetic shielding structure optimization design for wireless power transmission coil

open access: yesAIP Advances, 2017
In order to improve the performance of the wireless power transmission (WPT) system, a novel design scheme with magnetic shielding structure on the WPT coil is presented in this paper. This new type of shielding structure has great advantages on magnetic
Zhongyu Dai   +4 more
doaj   +1 more source

Prediction of magnetic shield plate performance using permeability in alternating micromagnetic fields

open access: yesAIP Advances, 2021
Magnetoencephalographs (MEGs) are highly sensitive to magnetic noises, and thus, a high performance magnetically shielded room (MSR) is essential. The shielding effect of a novel MSR should predicted to verify if it satisfies the required specifications ...
Mitsuru Sakakibara   +3 more
doaj   +1 more source

Functional Connectivity Linked to Cognitive Recovery After Minor Stroke

open access: yesAnnals of Clinical and Translational Neurology, EarlyView.
ABSTRACT Objective Patients with minor stroke exhibit slowed processing speed and generalized alterations in functional connectivity involving frontoparietal cortex (FPC). The pattern of connectivity evolves over time. In this study, we examine the relationship of functional connectivity patterns to cognitive performance, to determine ...
Vrishab Commuri   +7 more
wiley   +1 more source

Optimization of combined active-passive electromagnetic shielding system for overhead power lines magnetic field normalization in residential building space

open access: yesElectrical engineering & Electromechanics
Problem. Normalization of overhead power lines magnetic field level in residential building. Goal. Normalization of overhead power line magnetic field by optimization of combined electromagnetic shielding system, consisting of active and passive parts ...
B. I. Kuznetsov   +5 more
doaj   +1 more source

Electromagnetic Shielding Techniques in the Wireless Power Transfer System for Charging Inspection Robot Application

open access: yesInternational Journal of Antennas and Propagation, 2021
Aiming at eliminating the leakage of magnetic fields from the wireless power transfer (WPT) system, the structural and working characteristics of the WPT system for the inspection robot are analyzed and an electromagnetic shielding method combining ...
Chaoqun Jiao   +5 more
doaj   +1 more source

Feasibility and Tolerability of Performing Portable MRI for Neurological Disorders in an Outpatient Neurology Clinic: A Prospective Cohort

open access: yesAnnals of Clinical and Translational Neurology, EarlyView.
ABSTRACT Background Accessing brain magnetic resonance imaging (MRI) can be challenging, especially for underserved patients, which may lead to disparities in neurological diagnosis. Method This mixed‐methods study enrolled adults with one of four neurological disorders: mild cognitive impairment or dementia of the Alzheimer type, multiple sclerosis ...
Maya L. Mastick   +19 more
wiley   +1 more source

Enhancing Corrosion Resistance and Mechanical Strength of 3D‐Printed Iron Polylactic Acid for Marine Applications via Laser Surface Texturing

open access: yesAdvanced Engineering Materials, EarlyView.
Laser surface texturing significantly improves the corrosion resistance and mechanical strength of 3D‐printed iron polylactic acid (Ir‐PLA) for marine applications. Optimal laser parameters reduce corrosion by 80% and enhance tensile strength by 25% and ductility by 15%.
Mohammad Rezayat   +6 more
wiley   +1 more source

Home - About - Disclaimer - Privacy