Results 11 to 20 of about 26,775 (234)
A Novel Open-Loop Current Sensor Based on Multiple Spin Valve Sensors and Magnetic Shunt Effect with Position Deviation Calibration [PDF]
To address the demands for wide-range and high-precision current measurement, this paper proposes a novel current sensor design that integrates spin sensing technology, magnetic shunt effect, and a multi-sensor data fusion algorithm.
Tianbin Xu +6 more
doaj +2 more sources
This study investigated the effect of electromagnetic shunt dampers on the resonance amplitude reduction in a superconducting magnetic levitation system.
Kentaro Fujita, Toshihiko Sugiura
doaj +3 more sources
ObjectiveThe quantity of ultra-high field MRI neuroimaging studies has rapidly increased. This study tests function, safety, and image artifacts of two frequently implanted programmable ventriculo-peritoneal (VP) shunt valves in a 7T MRI system ...
Bixia Chen +6 more
doaj +3 more sources
Noninvasive Measurement of Cerebrospinal Fluid Flow in Shunted Hydrocephalus: Protocol for Scanner Calibration and Multisite Data Collection [PDF]
BackgroundVentricular shunts divert cerebrospinal fluid (CSF) in patients with hydrocephalus, which can be lifesaving. Untreated shunt failure may lead to increased intracranial pressure and neurological injury.
Jason M Toliao +16 more
doaj +2 more sources
Effect of Magnetic Shunts on Shell-Type Transformers Characteristics
A three-dimensional analysis of the leakage magnetic field in a transformer with beveled edges in a magnetic shunt is described. This paper contains a mathematical description of the finite element method used in performing numerical calculations ...
Bronisław Tomczuk, Dawid Weber
doaj +1 more source
Adjustable shunts and proton therapy: a magnetic combination
Due to evidence for proton beam therapy (PBT) in pediatric central nervous system (CNS) tumors, compact proton therapy systems became commercially available to allow better integration in a hospital setting. However, these systems have a non-zero magnetic field at the level of the patient.
Dietvorst, Sofie +4 more
openaire +3 more sources
A 76-year-old Japanese man with probable hereditary hemorrhagic telangiectasia (HHT) presented with hepatic arteriovenous malformation (AVM) and hyperintense T1 signal of the bilateral basal ganglia on magnetic resonance imaging.
Junichi Sakagami +7 more
doaj +1 more source
Introduction White matter changes (WMC) on brain imaging can be classified as deep white matter hyperintensities (DWMH) or periventricular hyperintensities (PVH) and are frequently seen in patients with idiopathic normal pressure hydrocephalus (iNPH ...
Carl Snöbohm +5 more
doaj +1 more source
For high-voltage shunt reactors with rods with non-magnetic gaps, an analytical method for calculating magnetic fluxes based on substitute circuits has been developed by substantiation by finite element modeling, and the calculation of main and ...
А.В. Басова +1 more
doaj +1 more source
Leakage Inductance Calculation for Planar Transformers With a Magnetic Shunt [PDF]
The magnetic shunt is generally inserted in a planar transformer to increase the leakage inductance, which can be utilized as the series inductor in resonant circuits such as the LLC resonant converter. This paper presents a calculation methodology for the leakage inductance of the transformer with a magnetic shunt by means of the stored magnetic ...
Zhang, Jun +4 more
openaire +1 more source