Results 141 to 150 of about 32,667 (253)

Lunar Portable Magnetometer

open access: yes, 1966
Technical drawing showing the layout of lunar surface magnetometer dust cover detail including labeled scale ...
Takahashi, Vitro
core   +1 more source

Photothermal–Magnetocaloric Coupled Evaporators for Actively Adjustable Water Evaporation and Oil–Water Purification in Complex Environments

open access: yesENERGY &ENVIRONMENTAL MATERIALS, EarlyView.
A photothermal–magnetocaloric coupled aerogel evaporator is developed for actively adjustable water evaporation in complex environments. Magnetocaloric heating provides active energy compensation under low‐light conditions and disrupts interfacial hydrogen‐bond networks to promote evaporation.
Jingbo He   +8 more
wiley   +1 more source

Magneto‐Electrochemical Effect on La‐Doped GaFeO3 as a Supercapacitor Electrode for Energy Storage

open access: yesElectron, EarlyView.
The electrochemical performance of La‐doped Gallium Ferrite (La‐doped GaFeO3 ${\text{GaFeO}}_{3}$) synthesizes via a conventional solid‐state reaction method; this has been studied by the application of an external magnetic fields. ABSTRACT The electrochemical performance of La‐doped GaFeO3 ${\text{GaFeO}}_{3}$ synthesizes via a conventional solid ...
Biswajit Sahoo   +5 more
wiley   +1 more source

Light‐Modulated Exchange Bias in Multiferroic Heterostructures

open access: yesElectron, EarlyView.
In this article, exchange bias and magnetization are modulated with visible light at room temperature in PMN‐PZT/FeGa/IrMn multiferroic heterostructures. Photostrictive effect is the main mechanism leading to the modulation of magnetic anisotropy and interfacial exchange bias coupling between the ferromagnetic and antiferromagnetic layers.
Huan Tan   +9 more
wiley   +1 more source

Lunar Portable Magnetometer

open access: yes, 1970
Technical drawing showing the layout of portable magnetometer battery pack assembly including labeled scale drawings.
Menefee, E.
core   +1 more source

Ni Nanoparticle‐Decorated Reduced Graphene Oxide Hybrids With Tunable Dielectric–Magnetic Synergy for Efficient Microwave Absorption

open access: yesElectron, EarlyView.
Optimized Ni nanoparticle loading on reduced graphene oxide creates abundant Ni/rGO heterointerfaces, enhancing interfacial polarization, conductive loss, magnetic loss, and impedance matching. The rGO/Ni‐5 hybrid achieves efficient microwave absorption at only 15 wt.% filler loading, delivering a minimum reflection loss of −35.5 dB and an effective ...
Zhurong Peng   +11 more
wiley   +1 more source

An Astatic Magnetometer with a Recording System

open access: yes, 2009
An astatic magnetometer used by means of a lamp and scale reading method was improved to record the remanent magnetization of rock sample. In order to detect the deflection of a suspended mirror of the magnetometer, solar cell (Photocell) was employed ...
YAMAZAKI, Teiji   +3 more
core  

Auditory gamma‐band synchronization and attentional performance in juvenile myoclonic epilepsy

open access: yesEpilepsia Open, EarlyView.
Abstract Objective Cognitive difficulties in juvenile myoclonic epilepsy (JME) are part of the clinical phenotype alongside epileptic seizures; however, the underlying neurophysiological mechanisms remain unclear. Auditory steady‐state responses (ASSRs) to repetitive 40‐ and 80‐Hz stimuli are widely used measures of gamma‐band oscillations (GBOs ...
Ryo Mitoma   +12 more
wiley   +1 more source

Field Use of a Magnetometer

open access: yes
This field activity builds upon the previous activity (Magnet as a Magnetometer) and provides students with first-hand use of a real magnetometer. The teacher will bury iron objects outdoors and have the students mark the area with a survey grid.

core  

Detection of previous knee injuries using lower limb‐worn inertial measurement units: A cross‐sectional machine‐learning study

open access: yesKnee Surgery, Sports Traumatology, Arthroscopy, EarlyView.
Abstract Purpose Previous knee injury increases the risk of subsequent injury, even after functional recovery, yet residual gait, running or load alterations often go undetected in routine assessment. Wearable inertial measurement units (IMUs) may enable scalable detection of such alterations outside laboratory settings.
Christina Valle   +11 more
wiley   +1 more source

Home - About - Disclaimer - Privacy