Results 111 to 120 of about 50,110 (299)
Lunar Portable Magnetometer reliability and quality assurance plan [PDF]
Sets forth the Reliability and Quality Assurance (R&QA) activities to be implemented during the development, fabrication, and testing of the Lunar Portable Magnetometer experiment.prepared by George E.
DeYoung, George E.
core
Non‐volatile voltage control of magnetic configurations is achieved in a strain‐coupled multiferroic heterostructure. Voltage pulses reversibly interconvert giant single‐domain and multidomain magnetic states, which remain stable at zero applied voltage. ABSTRACT Voltage control of magnetic states in multiferroic heterostructures represents a promising
M. Ghidini +11 more
wiley +1 more source
A project for a new alkali vapour magnetometer, optically pumped by a diode laser
We present here a project for the industrial development of a new magnetometer that is intended to achieve the highest performance in measuring geomagnetic field.
A. Donati +8 more
doaj +1 more source
Magneto‐NIR‐II‐programmed NFSH nanozymes integrate magnetic blood–brain barrier (BBB) translocation, CD44 targeting, multimodal imaging, and cascade catalytic therapy for glioblastoma. Alternating magnetic fields and NIR‐II irradiation amplify ferroptosis, release H2S, suppress autophagic and mitophagic repair, and reshape the immune microenvironment ...
Ruocan Liu +7 more
wiley +1 more source
Perovskite‐type oxide lanthanoid‐substituted BiCoO3 exhibits a reversible negative thermal expansion (NTE) originated from the coordination change from the CoO5 pyramid to the CoO6 octahedron due to melting of the dxy orbital ordering in the d6 electron configuration, and the 6.1% volume shrinkage in Bi0.82Nd0.18CoO3 is the largest ever observed in the
Yuki Sakai +10 more
wiley +1 more source
Borosilicate Glass MEMS Lorentz Force Magnetometer
This paper reports on a novel, miniaturized magnetomechanical transducer/sensor made of borosilicate glass with wide dynamic range. The prototype is manufactured with laser micromachining and ablation techniques.
Matthias Kahr +4 more
doaj +1 more source
As CMOS technology approaches fundamental energy limits, new paradigms for low‐power information processing are required. Magnetic systems are attractive for their spin transport, yet current‐induced magnetization control is energy inefficient. Multiferroic heterostructures enable energy‐efficient electric field manipulation of magnetism.
Donghyeon Lee +3 more
wiley +1 more source
Apollo 12 Lunar Surface Magnetometer anomalies investigation of failure of all sensor channels during each lunar night. [PDF]
This review has been undertaken to determine the probable cause of the magnetometer failure which first occurred on December 11 at low temperature during lunar night.Analysis and possible causes -- Most probable cause of failure -- Corrective ...
core
A nuclear‐pore‐inspired nested dual‐loop architecture redistributes electromagnetic energy through coupled transport, confinement, and dissipation pathways. Integrated with Co/Fe3O4 dual‐magnetic composites and topology optimization, the 11‐mm‐thick absorber delivers continuous 2–40 GHz attenuation, raises finite‐band structural utilization to 82%, and
Shaokang Liu +6 more
wiley +1 more source
A scalable process converts para‐aramid fibers into soft‐magnetic building blocks via micrometer‐thick Fe0.64Ni0.36 (Invar‐type) coatings. Assembled into paper, they form a hierarchical conductive network whose tunable permeability enables thin, lightweight microwave absorption in the low‐frequency (S‐band) regime.
You Wu +7 more
wiley +1 more source

