Results 91 to 100 of about 150 (139)
High Field Magnetooptics of Diluted Magnetic Semiconductors(Magnetooptics)
application/pdf Absorption and luminescence spectra of Cd_Mn_xSe (x=0.10 and 0.38) and reflectance spectra of Cd_Co_xSe (x=0.012) were investigated in high magnetic fields up to 25 T by a hybrid magnet and a magnetospectrometer with an optical fiber system.
openaire
In the visible-light region magneto optical Kerr measurements are affected by the thermal contraction of the crystal lattice. In lanthanides the magnetization-induced contraction (magnetostriction) is of the same order as the thermal contraction.
openaire +1 more source
Spin injection in graphene using ferromagnetic indium-cobalt van der Waals contacts
Sarkar S +9 more
europepmc +1 more source
Some of the next articles are maybe not open access.
Related searches:
Related searches:
Magnetooptic bounce-cavity modulator
Applied Optics, 1979In this paper a new type of magnetooptic modulator having a bounce-cavity structure is described. Direct amplitude modulation is achieved by utilizing the Faraday effect in conjunction with the differential reflectivity of dielectric mirrors for polarizations parallel to (TM) or perpendicular to (TE) the plane of incidence.
K Y, Lau, J C, Campbell, J, Stone
openaire +2 more sources
Dispersive magnetooptic filters
Applied Optics, 1982The anomalous dispersion of the Faraday rotation near optical resonance lines can be employed to build extremely narrowband filters (0.01 A) with a very wide field of view (+/-45 degrees ). This paper investigates the properties of these filters.
openaire +2 more sources
Digital magnetooptic disk drive
Applied Optics, 1984A magnetooptical disk drive employing some useful techniques for high performance has been developed for digital file use. A quadrilayer structure with AlN films promises high reliability of the medium as well as enhancement of Kerr rotation. The azimuth of the polarization plane is also increased by the beam splitter, of which Rs (reflectivity of S ...
T, Deguchi +5 more
openaire +2 more sources
Magnetooptical current transformer 3: Measurements
Applied Optics, 1980A laboratory setup of a magnetooptical current transformer was established. A ingle-mode fiber acts as both a measuring sensor and a transmission line. The overall measurement accuracy at room temperature within a primary current range 50-1200 A is better than 0.24%, the SNR at 1000 A is 85 dB.
H, Harms, A, Papp
openaire +2 more sources
Magnetooptic recording readout performance improvement
Applied Optics, 1988This paper describes magnetooptical (MO) readout and recording performance improvement that increase the MO disk drive performance. In regard to readout performance, a
T, Iwanaga +3 more
openaire +2 more sources
Magnetooptical current transformer 1: Principles
Applied Optics, 1980The principles of measuring currents in high-voltage lines by magnetooptical means are described. Particular attention is payed to using an optical fiber both as a transmission line and a measuring sensor. The influence of birefringence on the measuring signal is discussed.
A, Papp, H, Harms