Results 11 to 20 of about 2,666 (194)
The steel frame infilled with the autoclaved lightweight aerated concrete (AAC) masonry wall is widely applied in buildings. However, earthquake damage investigation has revealed that infill walls have a significant influence on the mechanical behaviors ...
You-Sheng Yu +3 more
doaj +1 more source
In this paper, a suitable damage index is demonstrated to assess the seismic-resistant design of masonry wall buildings reinforced with double x-bracing concrete frames.
Yossakorn Chonratana +1 more
doaj +1 more source
Analysis of behaviour of calcium silicate hollow blocks masonry subjected to the concentrated load
Loading of masonry with concentrated load is a sufficiently common case of loading which occurs due to structures of various purposes and sizes which lean against masonry wall, column or partition wall.
Mindaugas Zavalis
doaj +1 more source
In the face of the problem of waste disposal in the demolition of concrete structures, a composite wall composed of recycled concrete bricks and fly ash blocks was proposed, and based on the previous thermal performance research, its axial compression ...
Jianhua Li, Xueyong Xu, Xiaoqin Liu
doaj +1 more source
In this paper, an innovative strengthening system for masonry walls made of externally bonded Fabric-Reinforced Cementitious Matrix (FRCM) is presented. Due to the good mechanical properties and the compatibility with the architectural heritage, the FRCM
Riccardo Liberotti +3 more
doaj +1 more source
Unreinforced masonry has been used as a construction material for thousands of years. Whilesome of these structures survive to this day, these tend to have massive walls and would be unpractical formodern use. Unreinforced masonry can be reinforced with proper masonry techniques.
M. Djeffal, A. Merdas
openaire +1 more source
Numerical Simulation of the Blast Resistance of SPUA Retrofitted CMU Masonry Walls
Through numerical simulation, the blast-resistant performance of spray polyurea elastomer (SPUA) retrofitted concrete masonry unit (CMU) masonry infill walls under far-range blast loading was studied.
Yi Zhang +4 more
doaj +1 more source
The effects of masonry wall parameters on the water’s migration are deeply explored via the experimental laboratory simulation method. At this end, an experimental device consisting of a water tank in which a masonry block wall has a contact of around ...
Martial Nde Ngnihamye +5 more
doaj +1 more source
This study presents a finite element model to investigate the bidirectional seismic behavior of masonry infill walls. The test data are utilized to verify the numerical model.
Xiaomin Wang +3 more
doaj +1 more source
Partially grouted concrete masonry shear walls subject to in-plane shear load: a critical review [PDF]
: Although structures have been built from masonry for many years, little is still known about the behaviour of a wall subject to in-plane shear. This is particularly true of partially grouted concrete masonry.
Jianyixian Zhu, Nigel Shrive
doaj +1 more source