Results 311 to 320 of about 60,410 (404)

Can an increase in abutment screw length enable biomechanical advantages for implants with increased crown height space?

open access: yesJournal of Prosthodontics, EarlyView.
Abstract Purpose The purpose of this finite element analysis (FEA) study was to investigate how screw length and crown height affect the stresses generated in the implant‐abutment complex and alveolar bone for anterior single implants and whether the use of longer abutment screw would compensate for increased stresses originated from increased crown ...
Mert Keleş   +2 more
wiley   +1 more source

Effect of substructure fabrication method and design on the fracture resistance properties of metal–ceramic restorations

open access: yesJournal of Prosthodontics, EarlyView.
Abstract Purpose In metal–ceramic restorations, the substructure fabrication method and design may affect the prognosis of the prosthesis. This study evaluated and compared the fracture resistance of metal–ceramic restorations fabricated with different substructure fabrication methods using two different alloy powders and designs.
Young‐Hoon Lee   +4 more
wiley   +1 more source

Influence of prosthesis type and intraoral scanner‐based extraoral scanning protocol on the passive fit of CAD‐CAM verification devices

open access: yesJournal of Prosthodontics, EarlyView.
Abstract Purpose To evaluate the impact of different complete‐arch digital scanning techniques and prosthesis types on the passive fit of computer‐aided design and computer‐aided manufacturing (CAD‐CAM) verification devices. Materials and Methods Two different maxillary master casts with four multi‐unit abutment (MUA) implant analogs (FP‐1 and FP‐3 ...
Toshiki Nagai   +5 more
wiley   +1 more source

An assessment of clinical application of a new tooth notation for primary teeth [PDF]

open access: yes, 2015
Ashfaq, Akram   +5 more
core  

Clinical and esthetic outcomes of screw‐retained internal‐connection veneered zirconia‐ceramic CAD‐CAM abutments in single implant reconstructions: Five‐year results of a prospective case series investigation

open access: yesJournal of Prosthodontics, EarlyView.
Abstract Purpose To evaluate the long‐term clinical performance and survival, as well as the biological, esthetic, and technical complications of one‐piece, internally‐connected, screw‐retained, computer aided‐design and computer aided‐manufacturing (CAD‐CAM) veneered zirconia anterior and posterior implant‐supported single restorations fabricated on ...
Rafael del Castillo   +4 more
wiley   +1 more source

Virtual reconstruction of a provisional obturator using a mirroring technique in a patient with limited mouth opening

open access: yesJournal of Prosthodontics, EarlyView.
Abstract Capturing impressions for maxillary defect patients with trismus is challenging due to limited mouth opening and defect complexity. This study introduces an innovative digital technique that highlights virtual reconstruction through the integration of intraoral scanning and a mirroring approach.
Min‐Ju Ji   +3 more
wiley   +1 more source

Home - About - Disclaimer - Privacy