Results 81 to 90 of about 8,360 (240)
The color stability of maxillofacial silicones: A systematic review and meta analysis
This systematic review aims to identify and interpret results of studies that evaluated the changes in the color stability of maxillofacial prosthetic materials due to chemical instability of silicones and pigments and the effect of exposure to environmental conditions and aging factors on the same.This systematic review was conducted in accordance ...
Gupta, Priya +4 more
openaire +2 more sources
ABSTRACT Objectives To assess the influence of crown design, cement type, and margin depth on the removal efficiency of residual cement around single implant‐supported restorations. Methods Twelve mandibular models with a missing first molar were fabricated and provided with single implant analogs (centrally/distally placed) and two different crown ...
Shaza Bishti +4 more
wiley +1 more source
Interproximal Distance Analysis of Stereolithographic Casts Made by CAD-CAM Technology: An in Vitro Study [PDF]
Statement of problem The accuracy of interproximal distances of the definitive casts made by computer-aided design and computer-aided manufacturing (CAD-CAM) technology is not yet known.
Bansal, Naveen K. +2 more
core +2 more sources
It may not be possible to treat large maxillofacial defects by surgical reconstruction alone. Prosthetic rehabilitation is invariably required to restore esthetics and function.
Ruksana Farooqui +5 more
doaj +1 more source
Influence of Silver Nanoparticles on Color Stability of Room-Temperature-Vulcanizing Maxillofacial Silicone Subjected to Accelerated Artificial Aging [PDF]
Kaml Mohammed +2 more
openalex +1 more source
ABSTRACT Background/Objectives The use of mouthguards protects teeth and the supporting tissues against impacts. Digital impressions and 3D‐printed models can reduce manufacturing steps and minimize discomfort. This study evaluated the fit, comfort, and usability of custom‐made mouthguards, obtained by conventional and digital workflow, in amateur ...
Maryuri Macías Bautista +8 more
wiley +1 more source
Purpose: The aim of this study is to evaluate and compare the color stability of nanoparticles reinforced maxillofacial silicone after disinfection with neutral soap, 4% chlorhexidine, and ozone water.
Suji Daivasigamani +2 more
doaj +1 more source
A novel universal device "LINGUAL RING Ri.P.A.Ra" for TMDs and cranio-cervico-mandibular pains: preliminary results of a randomized control clinical trial [PDF]
The aim of this study was to evaluate functionality and clinical application of a novel immediate device in the treatment of temporomandibular disorders (TMDs).
Di Paolo, C +5 more
core +1 more source
ABSTRACT Objective This in vitro study evaluated the effects of composite material type, margin design (deep margin elevation vs. control), and thermomechanical aging on the marginal gap of CAD/CAM inlay restorations. Materials and Methods Standardized mesio‐occluso‐distal (MOD) inlay cavities were prepared in extracted human molars, with mesial ...
Zeliha Şanıvar Abbasgholizadeh +1 more
wiley +1 more source
Abstract Purpose Feeding plates for cleft palate patients have been used by clinicians for many years to temporarily close the oro‐nasal communication until definitive treatment with surgical techniques. The current in vitro study aimed to evaluate the adaptation of the feeding plates manufactured by two different techniques for three cleft types ...
Osman Akıncı +6 more
wiley +1 more source

