Association between IoT-driven dynamic pulmonary function monitoring and quality of life in community-dwelling patients with chronic obstructive pulmonary disease: a 2-year longitudinal study. [PDF]
Zhao M +8 more
europepmc +1 more source
Abstract Figure Legend Endurance‐trained runners completed a 5‐week hot‐water‐immersion (HWI) intervention (≥40°C, 45 min, five sessions per week) and a training‐matched control period in a cross‐over design. HWI induced a 33 g increase in haemoglobin mass (Hbmass) and a 10 mL expansion in left‐ventricular end‐diastolic volume (LVEDV), resulting in a 2.
Elliott J. Jenkins +7 more
wiley +1 more source
Emphysema Severity Index: a new spirometric parameter in epidemiology. [PDF]
Maio S +14 more
europepmc +1 more source
Breathing irregularities and postnatal hypoxaemia in an experimental model of essential hypertension
Abstract figure legend Neonatal spontaneously hypertensive rats (SHRs) exhibit inherent respiratory dysfunction in early life, including oscillatory breathing patterns and apnoeic events that cause oxygen desaturation and brain hypoxia, in addition to an impaired hypoxic ventilatory response.
Beatriz N. Vieira +7 more
wiley +1 more source
Marked Clinical and Functional Response to Tezepelumab After Failure of Anti-Interleukin-5 (Anti-IL-5) Therapy in Severe Asthma. [PDF]
Fujimoto M +3 more
europepmc +1 more source
ABSTRACT Purpose To enable MRI‐based nongated 3D depiction of forced expiration with both high spatio‐temporal resolution and fidelity of lung dynamics. Methods An undersampled 3D Fermat looped, orthogonally encoded trajectory (FLORET) was optimized for nonsegmented dynamic acquisitions during forced expiration and a corresponding model‐based ...
Sebastian Scheidel +6 more
wiley +1 more source
Exposure-response relationship between ambient PM<sub>2.5</sub> and SO<sub>2</sub> with COPD and SAD prevalence among individuals at high risk for COPD in Yunnan Province, China: a threshold analysis. [PDF]
Meng J +6 more
europepmc +1 more source
ABSTRACT Purpose Pulmonary hypertension is related to a 1‐year mortality ranging from < 5% to > 20% in low‐ and high‐risk groups. Right heart catheterization is the diagnostic gold standard, associated with a 1.1% rate of severe adverse events, posing the need for a non‐invasive diagnostic tool.
Markus Phillip Andersen +7 more
wiley +1 more source
Can laryngeal ultrasound detect laryngeal movements during mechanically assisted cough? [PDF]
Andersen TM +7 more
europepmc +1 more source
Incomplete Spoiling Correction for 3D T1$$ {T}_1 $$ Mapping
ABSTRACT Purpose Assess the impact of incomplete spoiling and spatial saturation on T1$$ {T}_1 $$ mapping using the variable flip angle (VFA) spoiled gradient recalled echo sequence (SPGR). Develop a correction for incomplete spoiling that results in an accurate estimate of T1$$ {T}_1 $$, essential for quantitative MRI applications.
Gabriela Belsley +3 more
wiley +1 more source

