Data inherent assessment of electrical equipment by failure pattern and self-evaluation decision-making algorithm. [PDF]
Aranizadeh A, Vahidi B, Khorsandi A.
europepmc +1 more source
ABSTRACT This paper presents a simplified equivalent circuit model (ECM) for the post‐arc sheath stage in DC vacuum circuit breakers and outlines the method for calculating circuit parameters using the particle‐in‐cell Monte Carlo collision (PIC‐MCC) method. The post‐arc sheath is modelled as a parallel combination of a variable resistor and a variable
Xubin Li +5 more
wiley +1 more source
Experimental performance examination of a coherence technique-based numerical differential current relay for AC machine stator windings protection. [PDF]
Mahmoud RA.
europepmc +1 more source
Surface Micro‐Discharge Plasma for Multiple Teeth Bleaching: Efficacy, Mechanism and Safety
ABSTRACT Hydrogen peroxide (H2O2) is the commonly‐used bleaching chemical in clinical practice, but its excessive concentrations can cause tooth damage. Atmospheric pressure cold plasma is considered a promising new technique for tooth bleaching. Surface micro‐discharge (SMD) devices can generate large‐scale plasma, which holds potential for treating ...
Ruike Chen +7 more
wiley +1 more source
Enhanced Wear Resistance and Thermal Dissipation of Copper-Graphene Composite Coatings via Pulsed Electrodeposition for Circuit Breaker Applications. [PDF]
Almonti D +3 more
europepmc +1 more source
ABSTRACT Large‐capacity generator circuit breaker (GCB) based on vacuum interrupter technology is the key power equipment to ensure the safe operation of the power system. When the short‐circuit current was forced to cross zero, the large‐capacity GCB was difficult to generate a zero‐voltage environment through freewheeling, the vacuum interrupter (VI)
Xiangyu Han +8 more
wiley +1 more source
Real-Time Evaluation of Ground Insulation Degradation and Fault Warning Method Under Multiple Operating Conditions for Train Traction Drive System. [PDF]
Cheng Z +5 more
europepmc +1 more source
ABSTRACT Currently, limited research exists on the structural response and protection methods of the converter transformer tank for ± 800 kV ultra‐high voltage direct current transmission project to high energy arc faults. This research investigates the dynamic response and the vulnerable areas of the ultra‐high voltage converter transformer under the ...
Ke Wang +5 more
wiley +1 more source
Multilayer Polyethylene Separator with Enhanced Thermal and Electrochemical Performance for Lithium-Ion Batteries. [PDF]
Liu J +10 more
europepmc +1 more source