Experimental performance examination of a coherence technique-based numerical differential current relay for AC machine stator windings protection. [PDF]
Mahmoud RA.
europepmc +1 more source
Data inherent assessment of electrical equipment by failure pattern and self-evaluation decision-making algorithm. [PDF]
Aranizadeh A, Vahidi B, Khorsandi A.
europepmc +1 more source
Real-Time Evaluation of Ground Insulation Degradation and Fault Warning Method Under Multiple Operating Conditions for Train Traction Drive System. [PDF]
Cheng Z +5 more
europepmc +1 more source
Hybrid GOA and PSO optimization for load frequency control in renewable multi source dual area power systems. [PDF]
Yameen MZ +5 more
europepmc +1 more source
Related searches:
Abstract Whether fault current can be broken quickly and reliably depends on dynamic characteristics of LC resonant commutation branch of mechanical DC circuit breaker.Thereby, the breaking characteristics of mechanical DC circuit breaker based on LC resonant commutation are studied in this paper. The topological structure and action time sequence of
Lu Qu, Yu Zhanqing, Rong Zeng
exaly +2 more sources
Transient Current Interruption Characteristics of a Novel Mechanical DC Circuit Breaker
IEEE Transactions on Power Electronics, 2018With the rapid development of multiterminal direct current (MTDC) grids, high-voltage direct current circuit breakers (HV-DCCB) capable of interrupting currents within 5 ms are in urgent demand. The mechanical DCCB has always been one of the main proposals for HV-DCCBs.
Bin Li, Weijie Wen, Yizhen Wang
exaly +2 more sources
Development and Testing of a 10-kA Hybrid Mechanical–Static DC Circuit Breaker
IEEE Transactions on Applied Superconductivity, 2011This paper presents the development and testing of the prototype of a hybrid mechanical-static dc circuit breaker (CB) for quench protection of superconducting magnets based on a mechanical switch paralleled to a static CB. In normal operation, the mechanical switch is closed and it handles the continuous flow of dc current, minimizing the on-state ...
Luca Novello, Alberto Ferro, Elena Gaio
exaly +4 more sources
Active Damping of Ultrafast Mechanical Switches for Hybrid AC and DC Circuit Breakers
IEEE Transactions on Industry Applications, 2017An active damping method for Thomson coil actuated ultrafast mechanical switches is proposed, including its control. Ultrafast mechanical switches are crucial for both dc and ac circuit breakers that require fast-acting current-limiting capabilities. However, fast motion means high velocity at the end of travel resulting in over-travel, bounce, fatigue,
Chang Peng, Wensong Yu, Qingyun Huang
exaly +2 more sources
Development of HVDC System-Level Mechanical Circuit Breaker Model
The main goal of the paper is the modelling of the mechanical direct current circuit breaker (DC CB) with active current injection that includes different circuit breaker characteristics. System level models provide adequate representation of the circuit
Marjan Popov, Siyuan Liu
exaly +2 more sources
Development and Testing of EHV Mechanical DC Circuit Breaker
2019 5th International Conference on Electric Power Equipment - Switching Technology (ICEPE-ST), 2019The paper presents recent development progress of a mechanical EHV DC circuit breaker with current injection scheme. An EHV level DC circuit breaker composes of multi-break HV vacuum interrupters, a current injection circuit and a metal oxide surge arrester (MOSA) energy absorption unit.
Sho Tokoyoda +5 more
openaire +1 more source