Results 21 to 30 of about 608 (121)

The possibilities with decision support systems in surgery of spine-pelvic complex (analytical review) [PDF]

open access: yesГений oртопедии, 2019
Objective To explore decision support systems (DSS) used in spine-pelvic surgery, analyze its functional possibilities and approaches that allow the surgeon to make a correct decision.
Anna S. Kolesnikova   +7 more
doaj   +1 more source

Hybrid Technique for Bone Graft Fixation in Arthroscopic Treatment of Anterior Recurrent Shoulder Dislocation. [PDF]

open access: yesArthrosc Tech
Abstract Many authors have introduced various methods for delivering bone grafts to the anterior rim of the glenoid using barreled cannulas and securing the grafts in the treatment of anterior recurrent shoulder instability, including both nonrigid and rigid fixation techniques. However, these instruments are not available in our country. Therefore, we
Nguyen Huu M   +5 more
europepmc   +2 more sources

Acoustic Prediction and Biomechanical Validation of Primary Stability in Uncemented Short-Stem Hip Prostheses: An Experimental Study. [PDF]

open access: yesJ Orthop Res
ABSTRACT In uncemented hip arthroplasty, achieving sufficient primary stability is essential for long‐term implant success. However, objective intraoperative assessment of fixation quality remains challenging. Acoustic analysis of stem impaction sounds offers a promising tool for real‐time evaluation, but its diagnostic accuracy and biomechanical ...
Jahnke A   +6 more
europepmc   +2 more sources

Safe Zones for Spinopelvic Screws in Patients With Lumbosacral Transitional Vertebra

open access: yesGlobal Spine Journal, 2023
Study Design: Retrospective matched-pair analysis. Objectives: Lumbosacral transitional vertebrae (LSTV) have a reported prevalence of 4-36% in the population.
Luis Becker MD   +5 more
doaj   +1 more source

Intraoperative fluoroscopically assessment underestimates the posterior tibial slope in open-wedge high tibial osteotomy. [PDF]

open access: yesJ Exp Orthop
Abstract Purpose To compare intraoperative and postoperative posterior tibial slope (PTS) measurements and determine whether unintended postoperative changes occur relative to preoperative values. Methods A total of 79 patients (81 knees) underwent open‐wedge high tibial osteotomy (owHTO) using patient‐specific instrumentation (PSI) for varus ...
Neopoulos G   +5 more
europepmc   +2 more sources

Isolated tibial deformity is the most prevalent varus pattern in North American patients undergoing medial opening wedge high tibial osteotomy. [PDF]

open access: yesJ Exp Orthop
Abstract Purpose To evaluate the location of deformity in varus alignment in a North American population and assess early total knee arthroplasty (TKA) conversion rates and TKA‐free survival following medial opening wedge high tibial osteotomy (MOWHTO) based on the bony deformity location. Methods A retrospective analysis was performed on patients with
Hiranaka T   +6 more
europepmc   +2 more sources

No clinical and functional benefit after medial congruent compared to ultra congruent total knee arthroplasty at 1 year: A prospective randomized controlled study

open access: yesKnee Surgery, Sports Traumatology, Arthroscopy, EarlyView.
Abstract Purpose Various conforming bearing designs are used during total knee arthroplasty (TKA), yet their impact on clinical outcomes remains uncertain. In recent years, the use of medial congruent (MC) and ultra congruent (UC) onlays has gained popularity.
Daniel Schrednitzki   +4 more
wiley   +1 more source

Percutaneous compression screw fixation for hinge fractures in distal femoral osteotomy does not compromise radiographic or clinical outcomes: A retrospective case‐control study

open access: yesJournal of Experimental Orthopaedics, Volume 13, Issue 3, July 2026.
Abstract Purpose The purpose of this study was to compare radiographic and clinical outcomes between patients undergoing distal femoral osteotomy (DFO) with intraoperative hinge fracture treated with percutaneous compression screw fixation and those without hinge fracture.
Victor Relot   +5 more
wiley   +1 more source

Reliabilitätsprüfung der softwaregestützten Torsionsmessung der unteren Extremitäten nach Waidelich [PDF]

open access: yes
Die Messung der Torsionswinkel an der unteren Extremität ist heutzutage aus dem klinischen Alltag der Orthopädie und Unfallchirurgie nicht mehr wegzudenken. Sie dient der Diagnostik, OP-Planung und auch der postoperativen Ergebniskontrolle.
Hagedorn (geb. Schuhmacher), Peter Stephan
core   +1 more source

Quantitative analysis of bony and soft tissue contributions to varus deformity across knee osteoarthritis stages

open access: yesJournal of Experimental Orthopaedics, Volume 13, Issue 2, April 2026.
Abstract Purpose To investigate the relationships among lower limb alignment parameters and quantitatively clarify the stage‐dependent contributions of bony morphology and soft tissue laxity to varus deformity across knee osteoarthritis stages. Methods We analysed 1346 knees of 673 participants in a community‐based cohort.
Kyota Ishibashi   +7 more
wiley   +1 more source

Home - About - Disclaimer - Privacy