Results 61 to 70 of about 630 (127)
Background/Objectives: Various parameters, like femoral offset and leg length, are associated with good patient outcomes after total hip arthroplasty.
Stefan van Drongelen +3 more
core +1 more source
International audiencePurpose: Preoperative digital planning of total hip arthroplasty (THA) anticipates difficulties while increasing implant survival. The objective was to establish the learning curve to produce a reliable and reproducible preoperative
Cypel, S. +4 more
core +1 more source
Impact of personalized alignment technique on implant components position in total knee arthroplasty
Introduction Due to substantial rates of dissatisfaction in patients with mechanical alignment in total knee replacement, surgeons began searching for alternative techniques to improve functional outcome.
Viktor V. Kuzin +3 more
doaj +1 more source
Ievads. Gūžas locītava ir visbiežāk endoprotezētā locītava valstī un operāciju skaitam ir tendence pieaugt, kas liek meklēt jaunus risinājumus, kā sniegt labākus un kvalitatīvākus rezultātus pacientiem.
Rozenbergs, Krišs
core
A Novel Tool for Collaborative and Blinded Orthopedic Image Analysis. [PDF]
Schippers P +6 more
europepmc +1 more source
Minimally Invasive Hip Arthroplasty via SuperPath Approach in Obese Patients – A Prospective Study
The use of minimally invasive techniques for total hip arthroplasty (THA) in at-risk patients is still debated. The purpose of this prospective study was to determine the clinical and radiographic results of obese patients undergoing THA compared with ...
André Busch +3 more
core +1 more source
Tibial Plateau Leveling Osteotomy (TPLO) is the most frequently performed technique to stabilize the stifle joint in dogs with cranial cruciate ligament rupture. This affection is the first cause of pelvic limb lameness in this species. Conventional preoperative two-dimensional (2D) planning using radiographic templates can improve osteotomy ...
openaire +1 more source
Final Femoral Rasp Predicts Intraoperative Stem Alignment in Primary Total Hip Arthroplasty Using a Cementless Triple-Tapered Stem. [PDF]
Ahlheit YA +6 more
europepmc +1 more source
High variability in the degree of liner stability ratio among glenoid components of different anatomical total shoulder arthroplasty systems. [PDF]
Shekhbihi A +5 more
europepmc +1 more source
Leg length and offset in short-stem total hip arthroplasty: is a single offset-implant sufficient to restore the hip rotation centre within a range of 5 mm? [PDF]
Olk F +6 more
europepmc +1 more source