Results 161 to 170 of about 1,599 (204)

A disposable, self-contained PCR chip. [PDF]

open access: yesLab Chip, 2009
Kim J, Byun D, Mauk MG, Bau HH.
europepmc   +1 more source

Impaired organization and function of myofilaments in single muscle fibers from a mouse model of Pompe disease.

open access: yesJ Appl Physiol (1985), 2010
Xu S   +6 more
europepmc   +1 more source

Comparative Assessment of PSI Air Oxidation Model Implementation in SCDAPSim3.5, MELCOR 1.8.6 and MELCOR 2.1

Annals of Nuclear Energy, 2015
Abstract The PSI air oxidation model has been successfully implemented in the lump parameter code MELCOR. The PSI air oxidation model treats oxygen as an active species and nitrogen as a catalyst that accelerates the oxidation kinetics. The essential feature of the model is the transition from parabolic to linear kinetics. The implementation has been
Leticia Fernandez-Moguel
exaly   +2 more sources

Melcor Developments Ltd.

Mergent's Dividend Achievers, 2006
AbstractProperty, Real Estate & Development (MIC: 8.3 SIC: 6552 NAIC: 237210)Melcor Developments is a real estate development company. Co. conducts business through four divisions. The Community Development division is engaged in the acquisition of land for development and sale for residential communities, multi‐family sites and commercial sites ...
  +6 more sources

Melcor Developments Ltd.

Mergent's Dividend Achievers, 2005
AbstractProperty, Real Estate & Development (MIC: 8.3 SIC: 6552 NAIC:237210)Melcor Developments is a real estate development company. Co. conducts business through four divisions. The Community Development division is engaged in the acquisition of land for development and sale for residential communities, multi‐family sites and commercial sites. Co.
  +5 more sources

Coupling of MELCOR With Surrogate Model for Quench Estimation of Conical Debris Beds

open access: yesAnnals of Nuclear Energy
The MELCOR code as a severe accident simulation tool does not have the capability to capture the quench process of a debris bed which may form in the wet cavity during a severe accident of light water reactors (LWRs).
Weimin Ma, Wanhong Wang
exaly   +2 more sources

Comparison of CORA and MELCOR Core Degradation Simulation and MELCOR Oxidation Model

Volume 6: Nuclear Education, Public Acceptance and Related Issues; Instrumentation and Controls (I&C); Fusion Engineering; Beyond Design Basis Events, 2014
MELCOR is widely used and sufficiently trusted for severe accident analysis. However, the occurrence of Fukushima has increased the focus on severe accident codes and their use. A MELCOR core degradation calculation was conducted at the University of Wisconsin – Madison.
Jun Wang   +7 more
openaire   +1 more source

Melcor Developments Ltd.

Mergent's Dividend Achievers, 2004
AbstractProperty, Real Estate &Development (MIC: 8.3 SIC: 6552 NAIC:237210)Melcor Developments is a real estate development company. Co. conducts business through four divisions. The Community Development division is engaged in the acquisition of land for development and sale for residential communities, multi‐family sites and commercial sites. Co.'
openaire   +2 more sources

Comparison of CORA & MELCOR core degradation simulation and the MELCOR oxidation model

Nuclear Engineering and Design, 2014
Abstract MELCOR is widely used and sufficiently trusted for severe accident analysis. However, the occurrence of Fukushima has increased the focus on severe accident codes and their use. A MELCOR core degradation calculation was conducted at the University of Wisconsin–Madison under the help of Sandia.
Jun Wang   +7 more
openaire   +1 more source