To meet the increasing requirements of membrane humidification in proton exchange membrane fuel cells (PEMFCs), a series of montmorillonite (MMT)/PEBAX® 1074 mixed matrix membranes (MMMs) were fabricated ...
Li Weiye +3 more
doaj +1 more source
Performance Analysis of a Hollow Fiber Membrane Humidifier Integrated with an Electric Heat Pump System in Office Environments [PDF]
This study proposes a system that integrates a hollow fiber membrane humidifier with an electric heat pump indoor unit to address the problem of low indoor humidity during office heating.
Oh Jeong-Min +3 more
doaj +1 more source
The impact of air contaminants on humidifier membrane performance
192203Membrane humidifiers are often used to increase the performance and lifetime of polymer electrolyte membrane fuel cells (PEMFC). In order to avoid possible problems and consequential costs in later fuel cell applications due to the degradation of ...
Kraus, Holger +13 more
core +1 more source
The effect of electrically heated humidifier on the body temperature and blood loss in spinal surgery under general anesthesia [PDF]
BackgroundGeneral anesthesia often produces some degree of hypothermia and hypothermia causes much more blood loss during surgery than normothermia. Electrically heated humidifiers (EHHs) have been used for patients under general anesthesia and in the ...
Hyun Kyu Lee +3 more
doaj +1 more source
In this study, a newly developed zero-dimensional electrochemical model was used for modeling and controlling proton-exchange membrane fuel cell (PEMFC) performance.
Tino Vidović +3 more
doaj +1 more source
Optimal sizing of gas-to-gas membrane humidifiers for proton exchange membrane fuel cell automotive systems [PDF]
External humidification using membrane humidifiers is an attractive technology used in controlling the humidity of proton-exchange membrane fuel cell (PEMFC) systems. Membrane humidifiers operate under passive conditions, requiring no external power, and
Ofoegbu, Chukwunyere
core +1 more source
THE DIFFERENCE BETWEEN BACTERIAL GROWTH IN HUMIDIFIER AND NON HUMIDIFIER AT THE PATIENT WHO GOT OXYGEN THERAPY [PDF]
Introduction: Humidifier is a device for delivering oxygen to the patients. Before using it, the humidifier tube should fill with sterile water. There was a recent study that administering oxygen less than five liter per minutes, the tube was not load ...
Abu Bakar, Hanny Handiyani, Krisna Yetti
core +3 more sources
Numerical Study of Membrane Humidifier Performance with Single Channel Serpentine Configuration on Both Wet and Dry Sides [PDF]
The simplest and most prevalent method for water management inside proton exchange membrane fuel cells is the moisturization of hydrogen gas and air (or oxygen) before fuel cell entrance.
Ebrahim Afshari, Nabi Jahantigh
doaj +1 more source
Severe neonatal legionellosis associated with use of home humidifiers – A case report
Neonatal Legionella pneumophila infection is rare and mortality is high. There has been limited success with the use of extracorporeal membrane oxygenation, with reported mortality in infants of 88%.
Rebecca Mitting +9 more
doaj +1 more source
Causative antigens of humidifier lung in vapor from a humidifier: A case report
A 68-year-old man exhibited fever and cough three weeks prior to hospital admission after three months of ultrasonic humidifier usage. Chest computed tomography showed bilateral ground-glass opacities, lymphocyte levels in the bronchoalveolar lavage ...
Kozo Morimoto +8 more
core +1 more source

