Results 21 to 30 of about 1,371,385 (242)

Effect of montmorillonite on PEBAX® 1074-based mixed matrix membranes to be used in humidifiers in proton exchange membrane fuel cells

open access: yese-Polymers, 2020
To meet the increasing requirements of membrane humidification in proton exchange membrane fuel cells (PEMFCs), a series of montmorillonite (MMT)/PEBAX® 1074 mixed matrix membranes (MMMs) were fabricated ...
Li Weiye   +3 more
doaj   +1 more source

Performance Analysis of a Hollow Fiber Membrane Humidifier Integrated with an Electric Heat Pump System in Office Environments [PDF]

open access: yesE3S Web of Conferences
This study proposes a system that integrates a hollow fiber membrane humidifier with an electric heat pump indoor unit to address the problem of low indoor humidity during office heating.
Oh Jeong-Min   +3 more
doaj   +1 more source

The impact of air contaminants on humidifier membrane performance

open access: yes, 2023
192203Membrane humidifiers are often used to increase the performance and lifetime of polymer electrolyte membrane fuel cells (PEMFC). In order to avoid possible problems and consequential costs in later fuel cell applications due to the degradation of ...
Kraus, Holger   +13 more
core   +1 more source

The effect of electrically heated humidifier on the body temperature and blood loss in spinal surgery under general anesthesia [PDF]

open access: yesKorean Journal of Anesthesiology, 2011
BackgroundGeneral anesthesia often produces some degree of hypothermia and hypothermia causes much more blood loss during surgery than normothermia. Electrically heated humidifiers (EHHs) have been used for patients under general anesthesia and in the ...
Hyun Kyu Lee   +3 more
doaj   +1 more source

Proton-Exchange Membrane Fuel Cell Balance of Plant and Performance Simulation for Vehicle Applications

open access: yesEnergies, 2022
In this study, a newly developed zero-dimensional electrochemical model was used for modeling and controlling proton-exchange membrane fuel cell (PEMFC) performance.
Tino Vidović   +3 more
doaj   +1 more source

Optimal sizing of gas-to-gas membrane humidifiers for proton exchange membrane fuel cell automotive systems [PDF]

open access: yes, 2019
External humidification using membrane humidifiers is an attractive technology used in controlling the humidity of proton-exchange membrane fuel cell (PEMFC) systems. Membrane humidifiers operate under passive conditions, requiring no external power, and
Ofoegbu, Chukwunyere
core   +1 more source

THE DIFFERENCE BETWEEN BACTERIAL GROWTH IN HUMIDIFIER AND NON HUMIDIFIER AT THE PATIENT WHO GOT OXYGEN THERAPY [PDF]

open access: yes, 2017
Introduction: Humidifier is a device for delivering oxygen to the patients. Before using it, the humidifier tube should fill with sterile water. There was a recent study that administering oxygen less than five liter per minutes, the tube was not load ...
Abu Bakar, Hanny Handiyani, Krisna Yetti
core   +3 more sources

Numerical Study of Membrane Humidifier Performance with Single Channel Serpentine Configuration on Both Wet and Dry Sides [PDF]

open access: yesJournal of Heat and Mass Transfer Research
The simplest and most prevalent method for water management inside proton exchange membrane fuel cells is the moisturization of hydrogen gas and air (or oxygen) before fuel cell entrance.
Ebrahim Afshari, Nabi Jahantigh
doaj   +1 more source

Severe neonatal legionellosis associated with use of home humidifiers – A case report

open access: yesClinical Infection in Practice, 2020
Neonatal Legionella pneumophila infection is rare and mortality is high. There has been limited success with the use of extracorporeal membrane oxygenation, with reported mortality in infants of 88%.
Rebecca Mitting   +9 more
doaj   +1 more source

Causative antigens of humidifier lung in vapor from a humidifier: A case report

open access: yes, 2023
A 68-year-old man exhibited fever and cough three weeks prior to hospital admission after three months of ultrasonic humidifier usage. Chest computed tomography showed bilateral ground-glass opacities, lymphocyte levels in the bronchoalveolar lavage ...
Kozo Morimoto   +8 more
core   +1 more source

Home - About - Disclaimer - Privacy