Results 191 to 200 of about 454,280 (280)

Arthroscopic Repair of Medial Meniscus Posterior Root Tear: Transtibial Fixation With 2 Lasso‐Loop Sutures and 1 Samsung Medical Center Sliding Knot for Tensioning Secured by a Tibial Button

open access: yesArthroscopy Techniques, EarlyView.
Abstract Medial meniscus posterior root tears disrupt the circumferential load‐transmission function of the meniscus and negatively affect knee biomechanics. This technical note describes a reliable and reproducible arthroscopic repair technique using 2 lasso‐loop sutures and 1 Samsung Medical Center sliding knot through a single transtibial tunnel ...
Nevzat Arican   +4 more
wiley   +1 more source

A Simple Knot Technique to Simultaneously Prevent Medial‐Row Suture Loosening and Lateral‐Row Anchor Failure in Double‐Row Rotator Cuff Repair

open access: yesArthroscopy Techniques, EarlyView.
Abstract We describe a simple knot‐tying technique to augment fixation during double‐row rotator cuff repair. After standard lateral‐row anchor placement and suture tensioning, the remaining suture limbs are secured with a surgeon's knot positioned flush against the bone‐anchor interface.
Weidong Wang   +3 more
wiley   +1 more source

Preperitoneal desufflation after peritoneal closure during TAPP repair: an intraoperative feasibility study. [PDF]

open access: yesBMC Surg
Mitura K   +8 more
europepmc   +1 more source

Intra‐articular Extender Button Deployment Without a Secondary Incision for Salvage of Compromised Femoral Cortical Fixation in Anterior Cruciate Ligament Reconstruction

open access: yesArthroscopy Techniques, EarlyView.
Abstract As suspensory fixation techniques for anterior cruciate ligament grafts gain popularity, so does the need to troubleshoot when intraoperative complications arise. A compromised lateral femoral cortex that cannot support the suspensory fixation is a complex intraoperative complication that can lead to graft failure.
Priya Singh   +3 more
wiley   +1 more source

All‐Arthroscopic Repair of Partial‐Thickness Upper Border Subscapularis Tear With a Resorbable Bioinductive Bovine Collagen Implant

open access: yesArthroscopy Techniques, EarlyView.
Abstract Partial‐thickness subscapularis tears are frequently underdiagnosed, and optimal management remains controversial. Bioinductive collagen implants have shown promising results in partial‐thickness superior rotator cuff tears but have not been described for partial subscapularis pathology.
Alec E. Winzenried, Sachin Allahabadi
wiley   +1 more source

In vivo evaluation of a novel mesh suture design for abdominal wall closure. [PDF]

open access: yesPlast Reconstr Surg, 2015
Souza JM   +3 more
europepmc   +1 more source

Arthroscopic Flipped Coracoid Transfer (Laterjet Procedure) With Endobutton Fixation for Anterior Shoulder Instability

open access: yesArthroscopy Techniques, EarlyView.
Abstract Glenoid bone loss is one of the most important risk factors for recurrent anterior shoulder instability. Transfer of the coracoid process is a well‐established procedure for this. In the classic Latarjet procedure, the subscapularis tendon is split and the graft is fixed with screws.
Thilo Patzer   +2 more
wiley   +1 more source

Home - About - Disclaimer - Privacy