Results 241 to 250 of about 454,280 (280)
Some of the next articles are maybe not open access.
Biomechanical Comparison of Tendon Coaptation Methods With a Meshed Suture Construct
The Journal of Hand Surgery, 2021Tendon-to-tendon attachment constructs for tendon reconstructions or transfers need to be secure in order to allow early mobilization after surgery. The purpose of this study was to biomechanically compare 2 common constructs secured with a novel mesh suture versus a nonabsorbable braided suture.We used 100 cadaveric tendons to create 5 different ...
Joshua Allan, Gillis +2 more
openaire +2 more sources
Mesh suture in the treatment of diaphragmatic hernias
Pirogov Russian Journal of SurgeryThe paper studies the results of surgical treatment of the first 25 patients with diaphragmatic hernias who underwent laparoscopic surgeries for hiatal hernias using polypropylene mesh sutures using the proprietary method. Material and methods. Polypropylene mesh strips were used instead of traditional sutures to seal the crura of the diaphragm in 25 ...
A.V. Abolmasov +3 more
openaire +2 more sources
Laparoscopic sutured closure with mesh reinforcement of incisional hernias
Hernia, 2007This study reports medium-term outcomes of laparoscopic incisional hernia repair.Laparoscopic repair was performed on 721 patients with ventral hernia. After adhesiolysis the defect was closed with no. 1 polyamide suture or loop. This was followed by reinforcement with intraperitoneal onlay repair with a bilayered mesh.Laproscopic repair of ventral ...
C, Palanivelu +5 more
openaire +2 more sources
Theoretic and Evidence-Based Laparotomy Closure with Sutures and Meshes
Plastic & Reconstructive Surgery, 2018Summary: The ultimate tensile strength of newly apposed tissue is the sum of the strength of the physical construct holding the tissues and the strength of biologic healing. For successful incisional hernia repair, the total strength of the repair must remain greater than the forces applied.
Lauren M, Mioton, Gregory A, Dumanian
openaire +2 more sources
Female Pelvic Medicine & Reconstructive Surgery, 2010
: To determine if suture type used for mesh attachment in abdominal sacrocolpopexy increases the rate of erosion/infection.: Two groups were temporally divided from June 1996 to May 2001 where braided permanent sutures (2-0 Ethibond, Ethicon, Somerville, New Jersey) were exclusively used for graft placement (n = 161) and from August 2001 to May 2006 ...
Jonathan P, Shepherd +3 more
openaire +2 more sources
: To determine if suture type used for mesh attachment in abdominal sacrocolpopexy increases the rate of erosion/infection.: Two groups were temporally divided from June 1996 to May 2001 where braided permanent sutures (2-0 Ethibond, Ethicon, Somerville, New Jersey) were exclusively used for graft placement (n = 161) and from August 2001 to May 2006 ...
Jonathan P, Shepherd +3 more
openaire +2 more sources
Mesh Sutured Repairs of the Abdominal Wall
2018When the ultimate tensile strength of newly apposed tissue remains above the level of the forces applied, the repair will remain intact. However, when distracting forces are greater than strength of a repair, the closure begins to gap as sutures tear through tissue at the suture/tissue interface (STI).
Gregory A. Dumanian, Steven T. Lanier
openaire +1 more source
Miscellaneous: Meshes and Sutures
2017Minimally invasive hernia repair has grown over recent years and along with this growth, the materials used have also evolved. Meshes and sutures are important parts of the surgical procedure regarding ventral hernia repair. This chapter describes all the characteristics of these materials regarding mechanical properties, handling, and reaction to ...
openaire +1 more source
Selective laser vaporization of polypropylene sutures and mesh
SPIE Proceedings, 2012Complications from polypropylene mesh after surgery for female stress urinary incontinence (SUI) may require tedious surgical revision and removal of mesh materials with risk of damage to healthy adjacent tissue. This study explores selective laser vaporization of polypropylene suture/mesh materials commonly used in SUI.
David Burks +3 more
openaire +1 more source
The Comparison of Self-Gripping Mesh and Sutured Mesh in Open Inguinal Hernia Repair
Annals of Surgery, 2014The aim of this study was to compare the postoperative chronic pain and other postoperative complications after the use of the self-gripping Progrip meshes and the application of conventional suture-fixed Lichtenstein procedure.Chronic pain after inguinal hernia repair is a complex problem. Many efforts have been put to reduce the postoperative chronic
Junsheng, Li, Zhenling, Ji, Yinxiang, Li
openaire +2 more sources
Retrospective comparison of mesh and sutured repair for adult umbilical hernias
Hernia, 2005Adult umbilical and paraumbilical hernia repair is associated with a high recurrence rate of 10-30%. Mesh repair has been reported to be associated with low recurrence rates. This study aims to compare sutured repair with prosthetic mesh repair to evaluate recurrence and infection rates.
P, Sanjay +4 more
openaire +2 more sources