Optimisation of zinc oxide surge arrester design using gravitational search algorithm and imperialist competitive algorithm [PDF]
Reducing electric field stress near the energised end of surge arresters is very important because it may increase the lifetime of the highly stressed ZnO column in vicinity of the high voltage electrode.
Abd Halim, Syahirah +5 more
core +3 more sources
Model Arrester SiC Menggunakan Model Arrester ZnO IEEE WG 3.4.11 [PDF]
Arrester model is needed to analyse the insulation coordination in power system. The model should give a suitable respon for varying transient fault. In this paper, we conduct simulation that modified from IEEE WG 3.4.11 model.
Haryono, T. (T) +2 more
core
The submodule in multilevel modular converters experiences a very fast transient overvoltage (VFTO) during switch operation of gas‐insulated switchgear, which also results in overvoltage on power devices, such as thyristors and insulated gate bipolar ...
Hong Shen +7 more
doaj +1 more source
Kajian Pemasangan Lightning Arrester pada Sisi Hv Transformator Daya Unit Satu Gardu Induk Teluk Betung [PDF]
Generally, The power centers are connected to the air transmission line, and the airborne transmission channel is susceptible to disturbances that are affected from outside the system, one of which is a lightning strike.
Jurnal, R. T. (Redaksi)
core
Prediction of ZnO Surge Arrester Degradation Based on Temperature and Leakage Current Properties [PDF]
Temperature and leakage current on the ZnO arrester are interrelated with each other. In low conduction region, voltage-current characteristics of ZnO surge arrester are highly dependent on temperature.
Abdul-Malek, Zulkarnain +5 more
core +2 more sources
Condition Monitoring of Zinc Oxide Surge Arresters [PDF]
Over voltages in power system may occur due to lightning, fault or switching operation. These overvoltages could reach dangerous amplitudes for power system apparatus.
Aulia +3 more
core +2 more sources
Conductive and inductive coupling between faulted power lines and buried pipeline by considering the effect of soil structure [PDF]
The AC total interference of faulted power lines to gas pipelines sharing the same right of way, which may pose a threat to operating personnel and equipment, was studied.
Abdul Malek, Z. +4 more
core
Mathematical Modeling of Passive Techniques Designed for PT Ferroresonance Suppression
Ferroresonance often inflicts severe damage on electrical equipment like potential transformers (PTs), surge arresters, and circuit breakers. In this paper, a new passive (P) technique using Cex (external parallel capacitor) is proposed and its ...
H. Tahami fard, S. Seyedtabaii
doaj +1 more source
Research on Field Source Characteristics of Leakage Current of Arrester Based on TMR Sensor. [PDF]
Fu Y +8 more
europepmc +1 more source
Effect of Metal Oxide Surge Arrester on Ferroresonance inVoltage Transformer Including Nonlinear Core Losses [PDF]
Hamid Radmanesh +2 more
openalex +1 more source