Results 121 to 130 of about 3,842 (216)
Transient electromagnetic simulations of substation earth grid for improving lightning withstand performance of a large power transformer [PDF]
Andresson, Einar +5 more
core +1 more source
Metal Oxide Surge Arresters Modelling in Temporary Overvoltage Conditions
Wichet Thipprasert, Ekkachai Chaidee
openaire +1 more source
Some of the next articles are maybe not open access.
Related searches:
Related searches:
Metal Oxide Surge Arrester: A Tool for Lightning Stroke Analysis
2021 IEEE International IOT, Electronics and Mechatronics Conference (IEMTRONICS), 2021Surge arrester is used to protect the equipment of electrical transmission and distribution systems from the effects of lightning and switching overvoltage. They are very much reliable devices which can work for decades without causing any problems provided they are properly designed, configured, and maintained.
M. Shaban
openaire +2 more sources
A Wide-Range Model for Metal-Oxide Surge Arrester
IEEE Transactions on Power Delivery, 2018This paper presents an electric model of a metal-oxide surge arrester (MOSA). The proposed electric model accurately represents the MOSA in a wide range of frequencies and amplitudes. The model was developed and validated based on MOSA electrical behavior in each one of the three operating regions of the zinc-oxide (ZnO) surge arresters, and in a ...
Valdemir S. Brito +3 more
openaire +2 more sources
Analysis of Thermal Effects for Polymer-Housed Metal-Oxide Surge Arrester Under Multiple Strokes
IEEE Transactions on Power Delivery, 2022Multiple strokes are the main factors affecting the safe and stable operation of power equipment. As the core lightning protection equipment, arresters are also frequently thermally collapsed due to multiple strokes.
Lin Huang +7 more
semanticscholar +1 more source
Development of controllable metal oxide surge arrester with trigger switch for 500kV AC power system
2023 12th Asia-Pacific International Conference on Lightning (APL), 2023In order to meet the requirement of deeply limiting the operating overvoltage level of a 500 kV AC power system, a controllable metal oxide surge arrester with a trigger switch was developed.
Wei Cao +5 more
semanticscholar +1 more source
Electric power systems research, 2022
The ageing in metal oxide surge arresters (MOSAs) is monitored by measuring their leakage current parameters. Particularly, the third harmonic component of resistive leakage current is directly correlated with the ageing and degradation of the arrester ...
Abdullah Munir +3 more
semanticscholar +1 more source
The ageing in metal oxide surge arresters (MOSAs) is monitored by measuring their leakage current parameters. Particularly, the third harmonic component of resistive leakage current is directly correlated with the ageing and degradation of the arrester ...
Abdullah Munir +3 more
semanticscholar +1 more source
IEEE Sensors Journal, 2021
Deposition of environmental pollutants like dust, salt, alkali etc. on the housing of metal oxide surge arrester can induces premature failure of it in long run. Therefore, reliability of an electrical system can be affected.
A. Das, D. Dey, B. Chatterjee, S. Dalai
semanticscholar +1 more source
Deposition of environmental pollutants like dust, salt, alkali etc. on the housing of metal oxide surge arrester can induces premature failure of it in long run. Therefore, reliability of an electrical system can be affected.
A. Das, D. Dey, B. Chatterjee, S. Dalai
semanticscholar +1 more source
Condition Assessment of Metal Oxide Surge Arrester Using Machine Learning Techniques
2023 IEEE 3rd Applied Signal Processing Conference (ASPCON), 2023The development of the electric power grid has boosted the use of metal oxide surge arresters in electrical systems. These devices serve as protective measures and aid in insulation coordination.
Joydip Dhar +4 more
semanticscholar +1 more source