Results 31 to 40 of about 124 (111)
Degradation of metal oxide surge arresters under simulated natural conditions [PDF]
The degradation of metal oxide surge arresters (MOSA) under continous operating voltage (C.O.V) with time, is a well known fact. But the contribution of transient overvoltages in the form of lightning surges, switching surges etc.-against which the arrester is used as a protection device, to the arrester degradation has not been studied much.
Vipin, PM +3 more
openaire +2 more sources
A Comprehensive Study on the Quality of Commercially Available Medium Voltage Surge Arresters
This paper presents a comprehensive study on the quality and reliability of commercially available medium voltage surge arresters, with particular emphasis on their electrical performance and structural degradation under aging conditions.
Kuba Wojcik +8 more
doaj +1 more source
The main weakness of the half-bridge modular multilevel converter-based high-voltage direct current (MMC-HVDC) system lies in its immature solution to extremely high current under direct current (DC) line fault.
Kaipei Liu +6 more
doaj +1 more source
Lightning strikes pose a growing threat to wind turbines, particularly due to climate change and technological advancements. This study focuses on the 9 MW Lamma Wind Power Plant (WPP) in Hong Kong, analyzing the effects of standard and non-standard ...
Moustafa Mohsen +3 more
doaj +1 more source
A Metal-Oxide Surge Arrester model with active V-I characteristics
Generally a model of Metal Oxide Surge Arrester (MOSA) for numerical analysis uses a nonlinear resistance. But actual Voltage-Current (V-I) characteristics of MOSA have a hysteresis loop in the time domain like the i-Φ characteristic of a transformer and frequency dependency.
Toyohisa Hagiwara +4 more
openaire +2 more sources
STUDY ON SURGE ARRESTER PERFORMANCE DUE TO LIGHTNING STROKE IN 20 KV DISTRIBUTION LINES
Electric energy has been transmiting from power station to end user with transmission and distribution lines.Lightning strokes are problems that occure in transmission and distribution lines and make them fault when theelectric energy were transmited ...
Agung Warsito +2 more
doaj
Condition Assessment of Metal Oxide Surge Arrester Based on Multi-Layer SVM Classifier
This paper introduces the indicators for surge arrester condition assessment based on the leakage current analysis. Maximum amplitude of fundamental harmonic of the resistive leakage current, maximum amplitude of third harmonic of the resistive leakage ...
M Khodsuz, M Mirzaie
doaj
The submodule in multilevel modular converters experiences a very fast transient overvoltage (VFTO) during switch operation of gas‐insulated switchgear, which also results in overvoltage on power devices, such as thyristors and insulated gate bipolar ...
Hong Shen +7 more
doaj +1 more source
Mathematical Modeling of Passive Techniques Designed for PT Ferroresonance Suppression
Ferroresonance often inflicts severe damage on electrical equipment like potential transformers (PTs), surge arresters, and circuit breakers. In this paper, a new passive (P) technique using Cex (external parallel capacitor) is proposed and its ...
H. Tahami fard, S. Seyedtabaii
doaj +1 more source
The role of surge arresters is vital in power systems' protection against transient overvoltages, which can arise due to occurrences like lightning strikes or switching operations.
Masume Khodsuz +2 more
doaj +1 more source

