Results 31 to 40 of about 80 (76)
ABSTRACT This paper investigates the generation mechanism of quasi‐power‐frequency resonant overvoltage triggered by multiple lightning strikes in high‐voltage alternating current (HVAC) systems equipped with shunt reactors. Based on field measurements from a 500 kV AC system, equivalent and simplified circuit models have been established to analyse ...
Tao Liang +7 more
wiley +1 more source
Surge Arrester Monitoring under Different Operating Conditions Using Bees-ANFIS
The essential role of surge arresters is equipment protection against over-voltages to increase system reliability. Different monitoring techniques have been used to diagnose surge arrester condition.
M. Khodsuz, S. Seyyedbarzegar
doaj
ABSTRACT To effectively suppress transient overvoltages in HVDC systems, the design and experimental validation of a multi‐module series controllable arrester are presented. The voltage‐limiting performance, series voltage equalisation capability, and robustness under fault conditions in high‐voltage scenarios require further research.
Tai Yang +4 more
wiley +1 more source
This paper aims to measure and analyze of the leakage current of 20 kV polymer and porcelain metal oxide surge arresters under humid ambient conditions by applying different voltages to the arresters terminal.
K. Mokhtari, M. Mirzaie, M. Shahabi
doaj
Study on the Power‐Frequency Arc Extinction Characteristics of Semi‐Closed Short‐Gap Device
ABSTRACT Multi‐chamber arc‐extinguishing devices have a simple structure and excellent arc‐extinguishing performance; thus, they have attracted considerable attention as lightning protection devices. However, the structural parameters of different models of the aforementioned devices vary, leading to inconsistent protection levels; therefore, the arc ...
Yeqiang Deng +4 more
wiley +1 more source
A Comprehensive Study on the Quality of Commercially Available Medium Voltage Surge Arresters
This paper presents a comprehensive study on the quality and reliability of commercially available medium voltage surge arresters, with particular emphasis on their electrical performance and structural degradation under aging conditions.
Kuba Wojcik +8 more
doaj +1 more source
Periodontal Medicine Rewired: Mechanisms Linking Periodontitis to Systemic Diseases
This review reorganizes decades of research in periodontal medicine into a multi‐dimensional framework, illustrating how periodontitis influences systemic health through at least seven interconnected mechanisms. ABSTRACT Periodontitis is now recognized not merely as a localized oral condition but as a systemic disease linked to over 70 communicable and
Mario Romandini +3 more
wiley +1 more source
Glioblastoma (GBM) is a highly aggressive brain tumor with a poor prognosis, driven by abnormal signaling pathways that promote growth and resistance to treatment. Conventional therapies are inadequate, highlighting the need for novel multitargeted approaches.
Mehrukh Zehravi +13 more
wiley +1 more source
River Sand and Gravel Mining: Global Drivers, Impacts, and Pathways for Sustainable Management
Abstract River sand and gravel are mined worldwide at volumes that now rival their natural replenishment, yet quantitative knowledge of this mining activity and its consequences lags far behind many other global environmental pressures. We synthesize 411 peer‐reviewed studies published since 1974 within a new Driver‐to‐Management Pathway for ...
Edward Park +25 more
wiley +1 more source
The main weakness of the half-bridge modular multilevel converter-based high-voltage direct current (MMC-HVDC) system lies in its immature solution to extremely high current under direct current (DC) line fault.
Kaipei Liu +6 more
doaj +1 more source

