Results 71 to 80 of about 520,057 (184)

Programmable Compliance in Small‐Diameter Vascular Grafts by Design of Melt‐Electrowritten Scaffold Architectures for In Situ Tissue Engineering

open access: yesAdvanced Healthcare Materials, Volume 15, Issue 2, 14 January 2026.
Small‐diameter vascular grafts with compliance tunable by design are fabricated via melt electrowriting. By controlling the winding angle of intertwined helical fibers, grafts with compliances matching those of human vessels, from veins to arteries, are realized. This holds the potential of avoiding a compliance mismatch, which has been identified as a
Kilian Maria Arthur Mueller   +8 more
wiley   +1 more source

Influence of sheath size on suction mini‐PCNL outcomes: An observational study from the EAU endourology section and the global suction in mini‐PCNL collaborative study group

open access: yesBJUI Compass, Volume 7, Issue 1, January 2026.
Abstract Objective We aim to evaluate the association between sheath size and outcomes in suction mini‐percutaneous nephrolithotomy (SM‐PCNL). Materials and Methods A prospective, multicentre study enrolled 1534 patients undergoing SM‐PCNL from March to November 2024 across 30 centres.
Vineet Gauhar   +17 more
wiley   +1 more source

Efficacy and Safety of Self-Expandable Covered Metallic Stents for Benign and Malignant Ureteral Obstructions: A Long-Term Retrospective Study

open access: yesMedicina
Background and Objectives: This study evaluated the safety and efficacy of long-term indwelling self-expandable covered metallic stents (UVENTA; Taewoong Medical Co., Ltd., Seoul, Republic of Korea) used to manage benign and malignant ureteral strictures.
Sae Woong Choi   +3 more
doaj   +1 more source

Update on ureteral stent technology

open access: yes, 2009
Ureteral stents are commonly used in urology but are frequently associated with patient discomfort, stent encrustation and stent-related infection. New biomaterials, coatings and designs have been designed to attempt to reduce these problems.
Ben H. Chew, Dirk Lange
core   +1 more source

Geometry‐Driven Biomechanical Optimization of Double‐J Ureteral Stents

open access: yesBioMed Research International, Volume 2026, Issue 1, 2026.
Ureteric stents are widely used to maintain ureteric patency; however, complications such as stent migration, ureteric irritation, and patient discomfort remain common. Although several geometric parameters of double‐J stents have been investigated in relation to urinary flow, stenosis, reflux, encrustation, stent length, and coil characteristics, the ...
Achmad Syaifudin   +4 more
wiley   +1 more source

Ureteroarterial Fistula from Ureteral Stump: A Challenging Case

open access: yesCase Reports in Urology, 2014
Ureteroarterial fistula (UAF) is a relatively rare condition with about 150 cases reported in the literature. Since it is a potentially life-threatening condition, a prompt diagnosis and treatment are crucial.
Pietro Pozzilli   +4 more
doaj   +1 more source

Predicting Abrasion Resistance in Thermoplastic Polyurethanes Using Machine Learning

open access: yesJournal of Applied Polymer Science, Volume 142, Issue 42, November 10, 2025.
Data‐driven prediction of TPU abrasion resistance using Gradient Boosting Regression (GBR), demonstrating superior performance through an ensemble of decision trees. ABSTRACT Abrasion resistance is a critical property of thermoplastic polyurethane (TPU), especially for applications in automotive, footwear, and medical devices where durability under ...
Sara Zahmatkesh   +3 more
wiley   +1 more source

Review of additively manufactured zinc alloys by laser powder bed fusion for biomedical applications

open access: yesRare Metals, Volume 44, Issue 11, Page 8262-8291, November 2025.
Graphical abstract AbstractZinc (Zn) and its alloys have emerged as promising candidates for biomedical materials, owing to their controlled degradation kinetics, intrinsic biocompatibility, and the release Zn2+ ions which are known to promote bone regeneration and tissue healing.
Xuan Yang   +5 more
wiley   +1 more source

Malignant ureteral obstruction: experience and comparative analysis of metallic versus ordinary polymer ureteral stents

open access: yesWorld Journal of Surgical Oncology, 2019
Background To study the outcome and experience of using metallic stents in treating patients with malignant ureteral obstruction (MUO). Methods Seventy-six patients with MUO were assigned to the metallic stent group (MSG) or the ordinary polymer stent ...
Yue Chen   +7 more
doaj   +1 more source

Metallic ureteral stents: a cost effective management in malignant ureteric obstruction [PDF]

open access: yes, 2014
OBJECTIVE: For patients requiring long-term ureteral stenting, conventional polymer stents necessitate multiple exchanges per year, bearing significant financial cost and likely detrimental effect on patients’ health.
Yuen, SKK, Ho, BSH, Yiu, MK, Ma, WK
core  

Home - About - Disclaimer - Privacy